Parameter
Size
No.
Application Function Select
2
Switch B
4th 3rd 2nd 1st
digit digit digit digit
n.
Pn00B
Application Function Select
2
Switch C
4th 3rd 2nd 1st
digit digit digit digit
n.
Pn00C
Setting
Name
Range
0000 to 1111
Parameter Display Selection
0
Setup parameters
1
All parameters
Alarm Gr.2 Stop Method Selection
0
Stops the motor by setting the speed reference to "0".
1
Same setting as Pn001.0 (Stops the motor by applying DB or by coasting).
Reserved (Do not change.)
Reserved (Do not change.)
0000 to 0111
Selection of Test without a Motor
0
Disables test without a motor.
1
Enables test without a motor.
Encoder Resolution for Test without a Motor
0
13 bits
1
20 bits
Encoder Type for Test without a Motor
0
Incremental encoder
1
Absolute encoder
Reserved (Do not change.)
Factory
Units
When Enabled
Setting
0000
After restart
0000
After restart
11.2 List of Parameters