Parameter
Size
No.
Model Following Control Bias
Pn144
2
(Reverse Direction)
Vibration Suppression 1
Pn145
2
Frequency A
Vibration Suppression 1
Pn146
2
Frequency B
Model Following Control Speed
Pn147
2
Feedforward
Compensation
2nd Model Following Control
Pn148
2
Gain
2nd Model Following Control
Pn149
2
Gain Compensation
Vibration Suppression 2
Pn14A
2
Frequency
Vibration Suppression 2 Com-
Pn14B
2
pensation
2
Control Related Switch
4th 3rd 2nd 1st
digit digit digit digit
n.
Pn14F
Anti-Resonance Control Related
2
Switch
4th 3rd 2nd 1st
digit digit digit digit
n.
Pn160
Pn161
2
Anti-Resonance Frequency
Setting
Name
Range
0 to 10000
10 to 2500
10 to 2500
0 to 10000
10 to 20000
500 to 2000
10 to 2000
10 to 1000
0000 to 0011
Model Following Control Type Selection
0
Model Following Control 1
1
Model Following Control 2
Tuning-less Type Selection
0
Tuning-less type 1
1
Tuning-less type 2
Reserved (Do not change.)
Reserved (Do not change.)
0000 to 0011
Anti-Resonance Control Selection
0
Does not use anti-resonance control.
1
Uses anti-resonance control.
Anti-Resonance Control Adjustment Selection
0
Does not adjust anti-resonance control automatically using utility function.
1
Adjusts anti-resonance control automatically using utility function.
Reserved (Do not change.)
Reserved (Do not change.)
10 to 20000
Factory
Units
When Enabled
Setting
0.1%
1000
Immediately
0.1 Hz
500
Immediately
0.1 Hz
700
Immediately
0.1%
1000
Immediately
0.1/s
500
Immediately
0.1%
1000
Immediately
0.1 Hz
800
Immediately
1%
100
Immediately
0011
After restart
0010
Immediately
0.1 Hz
1000
Immediately
11.2 List of Parameters
(cont'd)
Classifi-
Reference
cation
Section
Tuning
Tuning
Tuning
Tuning
Tuning
Tuning
Tuning
Tuning
Tuning
Reference
Section
6.3.1,
6.4.1,
6.5.1
Reference
Section
6.2.2
6.3.1,
Tuning
6.4.1,
6.5.1, 6.7.1
11
Tuning
11-19