2 Panel Operator

2.3.3 Setting Parameters

Step
5
<Note>
Setting negative numbers
• For the parameters that accept a negative value setting, display "0000000000" and then press the DOWN
Key to set negative numbers.
• When setting negative numbers, the value increases by pressing the DOWN Key and decreases by pressing
the UP Key.
• Press the DATA/SHIFT Key to move to other digits.
• A - (minus) sign is displayed when the top two digits are displayed.
(2) How to Select Functions Using Parameters
The parameter setting for selecting functions is used to select and set the function allocated to each digit dis-
played on the panel operator.
The example below shows how to change the setting of Pn000.1 (control method selection) of the Pn000
(basic function select switch 0) from speed control to position control.
Step
1
2
3
4
5
6
7
2-8
Display after
Operation
MODE/SET
Display after
Operation
MODE/SET
MODE/SET
MODE/SET
MODE/SET
Display flashes.
MODE/SET
MODE/SET
To enable the change in the setting, turn the power OFF and ON again.
Keys
Press the MODE/SET Key to save the value to the SER-
VOPACK. During saving, top two digits flash. After the
saving is completed, press the DATA/SHIFT Key for
approximately one second. "Pn522" is displayed again.
DATA/
Keys
Press the MODE/SET Key to select the parameter setting.
If Pn000 is not displayed, press the UP or the DOWN Key
to select Pn000.
DATA/
Press the DATA/SHIFT Key for approximately one sec-
ond. The current data of Pn000 is displayed.
DATA/
Press the DATA/SHIFT Key once to select the second digit
of current data.
"0" on the second digit will flash and be able to be
DATA/
changed.
Press the UP Key once to change to "n.0010."
(Set the control method to position control.)
DATA/
Press the MODE/SET Key. The value flashes and is saved.
The control method is changed from speed control to posi-
tion control.
DATA/
Press the DATA/SHIFT Key for approximately one sec-
ond. "Pn000" is displayed again.
DATA/
(cont'd)
Operation
Operation