1. Adjusting bolt
2. Pivot bolt
3. Belt adjusting bolt
4. 10 kg (22 lbs)
GENERATOR (WATER PUMP) BELT
BELT TENSION INSPECTION
1) Inspect belt cracks, cuts, deformation, wear and cleanliness.
2) Check belt for tension. Belt is in proper tension when it deflects
6 to 8 mm (0.24 – 0.31 in.) under thumb pressure (about 10 kg
or 22 lb.).
Belt tension "a" : 6 – 8 mm (0.24 – 0.31 in.) as deflection
NOTE:
When replacing belt with a new one, adjust belt tension to
5 – 7 mm (0.20 – 0.28 in.).
3) If belt is too tight or too loose, loosen adjusting bolt and pivot bolt
and adjust it to proper tension by turning belt adjusting bolt.
4) Tighten generator adjusting bolt and pivot bolt.
Tightening Torque
(a): 23 N·m (2.3 kg-m, 16.5 lb-ft)
(b): 50 N·m (5.0 kg-m, 36.5 lb-ft)
5) Connect negative cable at battery terminal.
REMOVAL
1) Disconnect negative cable at battery.
2) Loosen generator adjusting bolt, drive belt adjusting bolt and
generator pivot bolts.
When servicing vehicle equipped with A/C, remove compressor
drive belt before removing water pump belt.
3) Slacken belt by displacing generator and then remove it.
INSTALLATION
1) Install belt to water pump pulley, crankshaft pulley and genera-
tor pulley.
When servicing vehicle equipped with A/C, install compressor
drive belt, too.
2) Adjust belt tension.
For Adjustment of compressor drive belt tension, refer to SEC-
TION 0B of this manual.
3) Tighten water pump belt adjusting bolt and pivot bolts.
4) Connect negative cable at battery.
CHARGING SYSTEM 6H-13