SCAN TOOL DATA
DESIRED IDLE
(DESIRED IDLE
SPEED)
TP SENSOR VOLT
(
(THROTTLE POSITION
SENSOR OUTPUT
VOLTAGE)
INJ PULSE WIDTH
(
(FUEL INJECTION
PULSE WIDTH)
IAC FLOW DUTY
(IDLE AIR CONTROL
FLOWDUTY)
TOTAL FT B1
BATTERY VOLTAGE
CANIST PRG DUTY
(EVAP CANISTER
PURGE FLOW DUTY)
CLOSED THROT POS
(CLOSED THROTTLE
(CLOSED THROTTLE
POSITION)
FUEL CUT
FUEL CUT
RADIATOR FAN
(RADIATOR FAN
(RADIATOR FAN
CONTROL RELAY)
ELECTRIC LOAD
ELECTRIC LOAD
A/ C SWITCH
A/ C SWITCH
EGR VALVE
D
FUEL TANK LEVEL
BAROMETRIC PRESS
FUEL PUMP
BRAKE SW
BRAKE SW
BLOWER FAN
BLOWER FAN
FUEL PRES CONT
VALVE
(
(FUEL PRESSURE
CONTROL VALVE)
CONDITION
At idling with no load after warming up
Throttle valve fully closed
Ignition switch
ON/ engine
ON/ engine
stopped
Throttle valve fully open
At specified idle speed with no load after
warming up
At 2500 r / min with no load after warming up
At idling with no load after warming up
At specified idle speed after warming up
Ignition switch ON / engine stop
––––––––––––
Throttle valve at idle position
Throttle valve opens larger than idle position
When engine is at fuel cut condition
Other than fuel cut condition
Engine coolant temp.:
85 5C (1855F) or lower
Ignition switch
g
ON
Engine coolant temp.:
90 5C (1945F) or higher
Ignition switch ON / Headlight, small light and
rear window defogger all turned OFF
Ignition switch ON / Headlight, small light or
rear window defogger turned ON
Engine running after warming up, A / C not
operating
Engine running after warming up, A / C
operating
At specified idle speed after warming up
––––––––––––
––––––––––––
Within 3 seconds after ignition switch ON or
engine running
Engine stop at ignition switch ON.
Brake pedal is depressing
Ignition switch
g
ON
Brake pedal is releasing
Blower fan switch ON
Ignition switch
g
ON
Blower fan switch OFF
For a while after engine start, when engine
coolant temp. 1005C or higher and intake air
temp. 655C or higher
Other than above
ENGINE GENERAL INFORMATION AND DIAGNOSIS 6-31
REFERENCE VALUES
More than 0.1 V
Less than 4.8 V
2.0 – 3.6 msec.
2.0 – 3.6 msec.
Display the barometric pressure
750 r / min
5 – 25%
– 35 – +35%
12 – 15 V
0 – 100%
ON
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
ON
0%
0 – 100%
ON
OFF
ON
OFF
ON
OFF
ON
OFF

Hide quick links: