The setting enables that a PCAP-Trace of the phone can be logged on a
USB storage. This is an administrator feature which allows you to track all
kind of issues connected with the phone or the network traffic or SIP
signalling. The file holds the regular PCAP-Trace which can also be seen
on the web interface. But the trace on the USB storage is only limited by
the size of the storage. The trace is continuous. So it is possible to capture
events which happen rarely. In order to start the PCAP-Trace the USB
storage should hold the file pcap.flg in the root directory. So a PCAP-Trace
is not automatically saved to every USB storage that is plugged in. The
setting must be on, and a USB storage with the flag file pcap.flg must be
inserted to start the trace. We recommend that the file on the USB storage
is encrypted by also setting usb_storage_passphrase. Encrypting the file
is highly recommended, otherwise anyone could unplug the USB storage
and analyze the data. The feature is available on VTech phones with a
USB port.
on, off
off
usb_storage_siptrace
The setting enables that a SIP-Trace of the phone can be logged on a USB
storage. This is an administrator feature which allows you to track all kind
of issues connected with the phone or the network traffic or SIP signalling.
The file holds the regular SIP-Trace which can also be seen on the web
interface. But the trace on the USB storage is only limited by the size of the
storage. The trace is continuous. So it is possible to capture events which
happen rarely. In order to start the trace the USB storage should hold the
file siptrace.flg in the root directory. So a trace is not automatically saved
to every USB storage that is plugged in. The setting must be on, and a
USB storage with the flag file siptrace.flg must be inserted to start the
trace. We recommend that the file on the USB storage is encrypted by also
setting usb_storage_passphrase. Encrypting the file is highly
recommended, otherwise anyone could unplug the USB storage and
analyze the data. The feature is available on VTech phones with a USB
port.