Triumph Rocket III Classic Service Manual page 346

Table of Contents

Advertisement

Fuel System/Engine Management
EMS Ignition Voltage Input Circuit - Rocket III Touring
Fault Code
Possible cause
Action
P1659
EMS Ignition Voltage input circuit fault Disconnect ECM and proceed
pinpoint test 1:
Pinpoint Tests
Test
Result
Action
1 Check Fuse box Fuse 5 integrity
OK
Proceed to test 3
Faulty
Proceed to test 2
2 Check cable for short circuit:
- ECM pin A 19 to ground
OK
Replace Fuse 2 and proceed to test 3
to
Short circuit
Locate and rectify wiring fault, replace Fuse 2
3 Check cable and terminal integrity:
- ECM pin A19
- Alarm Connector pin 1
- Alarm Connector pin 2
- Right hand switch cube pin 5
- Right hand switch cube pin 6
and proceed to test 5
OK
Proceed to test 4
Faulty
Rectify fault, proceed to test 5
4 Check cable continuity:
OK
Proceed to test 5
r-----------~--------------------------~
- ECM pin A 19 to fuse box Fuse 5
Open circuit
Locate and rectify wiring, immobiliser or
, note that the engine stop switch must be
engine stop switch fault, proceed to test 5
in the 'RUN' position and any Alarm fitted
must be disarmed
5 Reconnect harness, clear fault code and run OK
engine to verify fault cleared
Action complete - quit test
Fault still present
Contact Triumph service
Circuit Diagram
11.142
Fuse Box
,-----,
1
5
1
I'
c:==J
IG
lOA
l _____
...1
Engine
Stop
Switch
Alarm
Control Unit
~~
GN-1 LGR-EJ
Service Manual - Rocket
1111
Classic
I
Touring
(

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rocket iiiRocket iii touring