:TIMebase:DELay

Command Syntax
:TIMebase:DELay <delay_value>
<delay_value> ::= time in seconds from trigger to the delay reference
The valid range for delay settings depends on the time/division
setting for the main time base.
The :TIMebase:DELay command sets the main time base delay. This delay
is the time between the trigger event and the delay reference point on the
screen. The delay reference point is set with the :TIMebase:REFerence
command (see
The :TIMebase:DELay command is obsolete and is provided for backward compatibility to
N O T E
previous oscilloscopes. Use the :TIMebase:POSition command (see
Query Syntax
:TIMebase:DELay?
The :TIMebase:DELay query returns the current delay value.
Return Format
<delay_value><NL>
<delay_value> ::= time from trigger to display reference in seconds
Example Code
Example program from the start:
page 614
Agilent 6000 Series Oscilloscopes Programmer's Reference
(see
page
564)
point on the screen.
page
326).
in NR3 format.
' TIMEBASE_DELAY - Sets the time base delay.
' is the internal time between the trigger event and the
' onscreen delay reference point.
' Set time base delay to 0.0.
myScope.WriteString ":TIMEBASE:DELAY 0.0"
Obsolete and Discontinued Commands
This delay
"VISA COM Example in Visual Basic"
5
page
323) instead.