  • Page 1 Agilent Infiniium 8000 Series Oscilloscopes Superior mixed-signal analysis and debug Data Sheet...
  • Page 2 The Infiniium 8000 Series offers bandwidths of 600 MHz and 1 GHz. Equipped with an XGA LCD display, scopes can be ordered as either a DSO or MSO. With built-in GPIB and low 5U high profile, it's ideal for rackmount applications.
  • Page 3 15 to 19. Sized to fit your environment Need to stack other instruments on top? Need to rackmount your scope? The Infiniium 8000 Series retains a traditional form factor with just a 5U high hight.
  • Page 4 Oscilloscope Capabilities Scope channels ensure superior viewing of signals under test. All models incorporate a powerful, feature-packed Infiniium oscilloscope with responsive deep memory. Up to 1 GHz bandwidth and 4 GSa/s high sample rates guarantee you’ll see a good representation of the analog characteristics of signals you’re testing Mask tests, histograms and a wide variety of functions provide deep signal analysis.
  • Page 5: Advanced Triggering

    Oscilloscope Capabilities (continued) Responsive deep memory With standard 4 Mpts, and up to 128 Mpts of memory, you can capture long time periods while retaining fast sample rates. Fast update rates mean your scope stays responsive with deep memory on, ensuring precise representation of analog signals.
  • Page 6 Industry’s only segmented memory for both analog and digital channels Capture short bursts without consuming memory during periods when the trigger con- dition is not met. Agilent is the only vendor that supports segmented memory capture on both analog and digital channels.
  • Page 7 Series one-box solution to validate the time and frequency domains. Extensive application software suite The 8000 Series provides wide application coverage for you to quickly and easily verify your designs. Application packages include jitter, DDR, USB, Ethernet, FlexRay, CAN, SPI, I...
  • Page 8 Infiniium Features (continued) DSO8064A/MSO8064A, DSO8104A/MSO8104A Simple zooming Zooming with Infiniium’s graphical user interface is simple and convenient. Just use the mouse to draw a box around the area of interest and click inside. Zoom uses the full display so you get meaningful vertical as well as horizontal resolu- tion gains.
  • Page 9 Infiniium Features (continued) DSO8064A/MSO8064A, DSO8104A/MSO8104A Web-enabled control For distributed teams, simply set up Infiniium on your LAN, and up to three users can access it from any Java-enabled Web browser. No special software is required. You can easily grab screen shots for a report, or troubleshoot designs from a remote location.
  • Page 10 Infiniium Features (continued) DSO8064A/MSO8064A, DSO8104A/MSO8104A High/low pass filter This function applies a real-time digital filter to the source waveform that you choose. This filtering feature enhances your ability to examine important signal components by filtering out unwanted frequency components. QuickMeasure and statistics Instantly make five common measurements on your signal, with easy-to-read statistics, by pressing the QuickMeas+ button on the front of your Infiniium.
  • Page 11 The Infiniium 8000 Series oscilloscopes ship with four 10073C 10:1 divider passive probes per scopeand probe accessory pouch. With both 50 Ω and 1 MΩ inputs, Infiniium 8000 Series scopes support a wide range of probes, including Agilent’s InfiniiMax Series probes.
  • Page 12 Drag-and-drop measurements from the measurement bar provide an intuitive way Get fast answers to your questions with to make a measurement on a particular the comprehensive built-in information cycle of your waveform. system. The task-oriented setup guide Up to 128 Mpts of MegaZoom fast deep provides step-by-step instructions for memory sustains maximum sample rates...
  • Page 13 MegaZoom technology enables you to quickly pan and zoom through the deepest waveforms for detailed analysis. Award-winning ease-of-use is made possible by attention to details like Infiniium’s analog-like front panel controls, color-coded to correspond to displayed waveforms. USB 2.0 port directly on front panel makes it easy to save files to a USB mass storage device.
  • Page 14 Agilent Infiniium Portfolio Agilent’s Infiniium lineup includes 8000, 9000 and 90000A Series oscilloscopes. These share a number of advanced hard- ware and software technology blocks. Use the following selection guide to determine which best matches your specific needs. Lowest cost, ideal for Widest range of applications.
  • Page 15 Infiniium Advanced Application Software The Agilent 8000 Series Infiniium oscilloscope offers a broad portfolio of add-on applications that enables you to customize your oscilloscope. These applications are available as add-on options at your initial scope purchase or as user-installed options at a later time. For more information about these options and to see if new applications have been added to our portfolio, please visit www.agilent.com/find/8000scope-apps.
  • Page 16 InfiniiScan event identification software (Option 009 or N5415A) The Agilent InfiniiScan event identification software quickly and easily identifies signal integrity issues. This innovative software scans through thousands of acquired waveforms per second to help isolate anomalous signal behavior.
  • Page 17 • Fixtures available: N5395B or N5395C or N5395C Ethernet test fixtures and N5396A jitter test cable • Supports 1000Base-T disturbing signal measurements with the use of 33250A arbitrary waveform generators • Supports return loss measurements with most HP/Agilent vector network analyzers...
  • Page 18 USB-IF MATLAB scripts with MATLAB’s runtime engine embedded in the oscilloscope. Results are displayed in a flexible report format with margin analysis. The Infiniium 8000 Series with bandwidths of 600-MHz and 1 GHz can appropriately test USB 2.0 low- and full-speed buses. The E2646A SQiDD test fixture is available for making the physical connection between the Infiniium oscilloscope and the device under test.
  • Page 19 Any program that can be run under Windows XP can be launched from the Infiniium scope user interface or front panel, including applications such as Agilent VEE, Microsoft Excel, or MATLAB.
  • Page 20: Recommended Probes

    In addition, a selection of probes that specifically enhances or utilizes Infiniium 8000 Series are also listed. For more complete information on Agilent probing solutions please see the Oscilloscope Probes and Accessories Selection Guide (Agilent publication number 5989-6162EN).
  • Page 21 Infiniium Performance Characteristics Vertical: scope channels DSO8064A, MSO8064A, DSO8104A, MSO8104A Input channels DSO8064A/DSO8104A: 4 analog MSO8064A/MSO8104A: 4 analog + 16 digital Analog bandwidth at 50 Ω (–3 dB) DSO8064A/MSO8064A: 600 MHz DSO8104A/MSO8104A: 1 GHz Calculated rise time at 50 Ω DSO8064A/MSO8064A: 583 ps DSO8104A/MSO8104A: 350 ps Input impedance...
  • Page 22 Infiniium Performance Characteristics (continued) Vertical: DSO/MSO8064A DSO/MSO8104A Analog noise floor Vrms Vrms Vp-p Vp-p Vrms Vp-p Vp-p Volts/div Vrms 50 Ω 50 Ω 1 MΩ 50 Ω 1 MΩ 1 MΩ 50 Ω 1 MΩ Full bandwidth 5 mV 204.8 µV 219.8 µV 1.61 mV 1.65 mV 285.4 µV 283.8 µV...
  • Page 23 Infiniium Performance Characteristics (continued) Horizontal DSO8064A, MSO8064A, DSO8104A, MSO8104A DSO8064A/MSO8064A DSO8104A/MSO8104A Main time base range 500 ps/div to 20 s/div 200 ps/div to 20 s/div Horizontal position range 0 to ± 200 s Delayed sweep range 1 ps/div to current main time base setting Resolution 4 ps Time scale accuracy...
  • Page 24 Infiniium Performance Characteristics (continued) Acquisition: Scope channels DSO8064A, MSO8064A, DSO8104A, MSO8104A Real time sample rate (max) 2 channels 4 GSa/s Each channel 2 GSa/s Equivalent time sample rate (max) 250 GSa/s Memory depth 2 channels/4 channels Standard 8 Mpts/4 Mpts Option 080 16 Mpts/8 Mpts Option 160...
  • Page 25 Infiniium Performance Characteristics (continued) Trigger: Scope channels DSO8064A, MSO8064A, DSO8104A, MSO8104A Sensitivity Internal DC to 600 MHz: 0.6 div 600 MHz to 1 GHz: 1.5 div (50 Ω) Auxiliary DC to 600 MHz: 300 mVp-p Level range Internal ± 8 div from center screen (1 MΩ) ±...
  • Page 26 Infiniium Performance Characteristics (continued) Software trigger (InfiniiScan event identification software (Option 009)) Trigger modes Generic serial Software triggers on NRZ-encoded data up to 80-bit pattern. Supports multiple clock data recovery methods including constant frequency, 1st order PLL, 2nd order PLL, explicit clock, explicit 1st order PLL, 2nd order PLL (requires N5384A except for the constant frequency).
  • Page 27 Measurements included: mean, standard deviation, mode, peak-to-peak, median, total hits, peak (area of most hits), and mean ± 1, 2, and 3 sigma. Mask testing Allows pass/fail testing to user-defined or Agilent-supplied waveform templates. AutoMask Allows user to create a mask template from a captured waveform and define tolerance range in time/voltage or percentage. Test modes include test forever, test to specified time or event limit, and stop on failure.
  • Page 28 Infiniium Performance Characteristics (continued) Display Display 8.4 inch color XGA TFT-LCD with touch screen Intensity grayscale 256-level intensity-graded display Resolution 1024 pixels horizontally x 768 pixels vertically Annotation Up to 12 labels, with up to 100 characters each, can be inserted into the waveform area Grids Can display 1, 2 or 4 waveform grids Waveform styles...
  • Page 29: General Characteristics

    Infiniium Performance Characteristics (continued) General characteristics DSO8064A, MSO8064A, DSO8104A, MSO8104A Temperature Operating 0 °C to + 50 °C Non-operating –40 °C to + 70 °C Humidity Operating Up to 95% relative humidity (non-condensing) at +40 °C Non-operating Up to 90% relative humidity at +65 °C Altitude Operating Up to 4,600 meters (15,000 feet)
  • Page 30: Memory Options

    Memory can be added both at the time of initial purchase and after with a user installed option. For a comprehensive list and selection criteria, refer to the Oscilloscopes Probes and Accessories Selection Guide (Agilent publication number 5989-6162EN). Or visit our Web site at www.agilent.com/find/scope_probes.
  • Page 31 Warranty Select coverage Included 3-year warranty (return to Agilent), standard R-51B-001-5Z 5-year warranty assurance plan (return to Agilent): Priority warranty service includes one- time coverage for an EOS/ESD failure. Calibration Select Agilent Calibration Plan R-50C-011-3 3-year calibration assurance plan (return to Agilent): Priority calibration service covering all calibration costs for 3 years;...
  • Page 32: Related Literature

    Data Sheet 5989-4605EN N5430A Infiniium User-Defined Function Application for Infiniium Oscilloscopes Data Sheet 5989-5632EN 8000 Series Oscilloscopes – The Best Combination of Signal Viewing and Analysis Brochure 5989-5806EN Agilent N5433A Infiniium MDO FPGA Dynamic Probe for Altera Data Sheet 5989-5940EN...
  • Page 33 A personalized view into the information most relevant to you. www.agilent.com/find/contactus www.lxistandard.org LAN eXtensions for Instruments puts the power of Ethernet and the Americas Web inside your test systems. Agilent is a founding member of the Canada (877) 894 4414 LXI consortium. Brazil...