:TRIGger:FLEXray:TIME:SEGMent

Command Syntax
:TRIGger:FLEXray:TIME:SEGMent <segment_type>
<segment_type> ::= {STATic | DYNamic | SYMbol | IDLE}
The :TRIGger:FLEXray:TIME:SEGMent command sets the FlexRay segment
type. The segment setting is only valid when the FlexRay trigger mode is
set to TIME.
This command is only valid when the FLEXray triggering and serial decode option (Option
N O T E
FRS) has been licensed.
Query Syntax
:TRIGger:FLEXray:TIME:SEGMent?
The :TRIGger:FLEXray:TIME:SEGMent? query returns the current segment
setting for the FlexRay time trigger setup.
Return Format
<segment_type><NL>
<segment_type> ::= {STAT | DYN | SYM | IDLE}
See Also
Agilent 6000 Series Oscilloscopes Programmer's Reference
(see
page
564)
"Introduction to :TRIGger Commands"
":TRIGger:MODE"
on page 338
":TRIGger:FLEXray:TRIGger"
Commands by Subsystem
on page 332
on page 381