Infiniivision 7000b series oscilloscopes
Hide thumbs Also See for InfiniiVision 7000B:

Advertisement

Quick Links

Agilent Technologies
InfiniiVision 7000B Series Oscilloscopes
Data Sheet
Engineered for the best signal visibility

Advertisement

loading

Summary of Contents for Agilent Technologies InfiniiVision 7000B

  • Page 1 Agilent Technologies InfiniiVision 7000B Series Oscilloscopes Data Sheet Engineered for the best signal visibility...
  • Page 2 See the InfiniiVision 7000B Series oscilloscope. The InfiniiVision 7000B Series offers bandwidths up to 1 GHz. Each model, equipped with a large 12.1” XGA LCD display, comes in a whisper-quiet package that is just 6.5” deep and weighs only 13 pounds.
  • Page 3 What gives the InfiniiVision 7000B Series the best signal visibility? 1. Biggest display Oscilloscopes are visual tools and larger, high-resolution screens make the product better. Bigger displays have become increasingly important as general purpose scopes need more space to display digital waveforms and serial decode traces in addition to traditional analog waveforms.
  • Page 4 4-channel model to acquire and decode these serial buses. Serial: Hardware-accelerated decode and Capture long streams of serial data and gain fast insight into your problems. Agilent 7000B Series oscilloscopes provide the best serial protocol capabilities in their class –...
  • Page 5: Other Useful Features

    Easy software upgrades. System software is stored in flash ROM that can be upgraded from the scope’s built-in USB port or LAN. You can find the latest system and IntuiLink software at: Digital signals can be displayed www.agilent.com/find/7000Bsw individually or as overlayed bus values.
  • Page 6 Oscilloscope vendors usually specify what their scope’s “best-case” waveform update rates are. Some scope architectures suffer from factors that can seriously degrade the “best-case” update rates spec. Agilent’s 7000B Series architecture delivers the fastest update rate when using: Improves instrument responsiveness •...
  • Page 7 20 ns/div Turn on serial decode * Agilent and LeCroy memory depth selection was automatically selected. Memory depth = display window times sample rate with up to 8 Mpts for Agilent. ** Tek measurements taken with version 2.13 firmware. Seeing subtle signal detail and infrequent events requires a scope with fast waveform update rates. Don’t take a scope vendor’s banner waveform update rate specification at face value.
  • Page 8: Software Applications

    Software applications Mask testing (N5455A or Option LMT) Agilent’s mask test option (Option LMT or N5455A) for InfiniiVision Series oscilloscopes pro- vides a fast and easy way to test your signals to specified standards, and uncover unexpected signal anomalies, such as glitches. Mask testing on other oscilloscopes is based on software- intensive processing technology, which tends to be slow.
  • Page 9 FPGA dynamic probe application (N5406A for Xilinx, N5434A for Altera) Give your MSO internal FPGA visibility. Agilent’s MSO FPGA dynamic probe provides internal FPGA visibility and quick instrument setup using an innovative core-assisted debug approach.
  • Page 10 Need to make power measurements with your scope? Agilent’s power application provides a full suite of power measurements that run on a PC connected to an InfiniiVision 7000B Series oscilloscope. Make more accurate power supply efficiency measurements by using an U1880A deskew fixture to deskew your voltage and current probes.
  • Page 11: Probes And Accessories

    Included with all MSO models is a logic probe with 2x8 flying leads (includes 20 IC clips and five ground leads) For more comprehensive information, refer to the Agilent 5000, 6000 and 7000 Series Oscilloscopes Probes and Accessories Data Sheet (with Agilent lit number 5968-8153EN).
  • Page 12 The 7000 B Series oscilloscopes follow specified LAN protocols and adhere to LXI requirements such as a built-in Web control server, IVI-COM driver, and easy- to-use SCPI commands. The standard Agilent I/O Library Suite makes it easy to configure and integrate instruments in your system.
  • Page 13 Agilent InfiniiVision Portfolio Agilent’s InfiniiVision lineup includes 2000X, 3000X, 6000, and 7000B Series oscilloscopes. These share a number of advanced hard- ware and software technology blocks. Use the following selection guide to determine which scope best matches your specific needs.
  • Page 14 Agilent InfiniiVision 7000B Series oscilloscopes: Engineered for the best signal visibility 12.1” large display makes it easier to view analog, digital and serial signals. High-resolution color display with XGA resolution and 256 levels of intensity reveals subtle details that most scopes won’t show you.
  • Page 15 Intensity knob allows you to see the right level of waveform detail, just like an analog scope. AutoProbe interface automatically configures the attenuation ratio of the probe and provides probe power for Agilent’s active probes. Dedicated front panel controls make it easy to access the most common scope controls, including vertical and horizontal scaling.
  • Page 16: Performance Characteristics

    Performance characteristics Acquisition: scope channels Sample rate MSO/DSO701xB: 2 GSa/s each channel MSO/DSO703xB: 2 GSa/sec each channel MSO/DSO705xB, 710xB: 4 GSa/sec half channel*, 2 GSa/sec each channel Equivalent-time sample rate: 400 GSa/s (when real-time mode is turned off) Maximum memory depth 2 channels/4 channels Standard 8 Mpts/4 Mpts...
  • Page 17 Probe ID Auto probe sense and AutoProbe interface Agilent- and Tektronix-compatible passive probe sense Denotes warranted specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and ±10 °C from firmware calibration temperature. 2 mV/div is a magnification of 4 mV/div setting for 350 MHz to 1 GHz models. For vertical accuracy calculations, use full scale of 16 mV for 1 mV/div sensitivity setting...
  • Page 18 Performance characteristics (continued) Vertical system: scope channels (continued) ESD tolerance ±2 kV Noise, RMS, input shorted MSO/DSO701xB: 0.50% FS or 300 µV, whichever is greater MSO/DSO703xB: 0.50% FS or 300 µV, whichever is greater MSO/DSO705xB: 0.50% FS or 360 µV, whichever is greater MSO/DSO710xB: 0.65% FS or 360 µV, whichever is greater DC vertical gain accuracy* ±2.0% full scale...
  • Page 19 Performance characteristics (continued) Horizontal Range MSO/DSO701xB: 2 nsec/div to 50 sec/div MSO/DSO703xB: 2 nsec/div to 50 sec/div MSO/DSO705xB: 1 nsec/div to 50 sec/div MSO/DSO710xB: 500 psec/div to 50 sec/div Resolution 2.5 ps Time scale accuracy* ≤ ± (15+2* (instrument age in years)) ppm Vernier 1-2-5 increments when off, ~25 minor increments between major settings when on Delay range...
  • Page 20 Performance characteristics (continued) Trigger system (continued) Selections Edge, pulse width, pattern, TV, duration, sequence, CAN, LIN, USB, I C, SPI, Nth edge burst, RS-232 with Option 232 Edge Trigger on a rising, falling, alternating or either edge of any source Pattern Trigger at the beginning of a pattern of high, low, and don’t care levels and/or a rising or falling edge established across any of the analog and digital channels, but only after a...
  • Page 21 AC (~3.5 Hz), DC, noise reject, HF reject and LF reject (~50 kHz) Probe ID Auto probe sense and AutoProbe interface Agilent- and Tektronix-compatible passive probe sense Denotes warranted specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and ±10 °C from firmware calibration temperature.
  • Page 22 Performance characteristics (continued) Display system Display 12.1-inch (255 mm x 184 mm) diagonal color TFT LCD Throughput of scope channels Up to 100,000 waveforms/sec in real-time mode Resolution XGA – 768 vertical by 1024 horizontal points (screen area); 640 vertical by 1000 horizontal points (waveform area) 256 levels of intensity scale Controls Waveform intensity on front panel.
  • Page 23 USB (USBTMC-USB488): 3.5 Mbytes/sec 100 Mbps LAN (TCP/IP): 1 Mbytes/sec Supported printers via USB For a list of currently supported printers visit www.agilent.com/find/InfiniiVision-printers General characteristics Physical size (WxHxD) 17.9” x 11.7” x 8.6” (45.4 cm x 29.8 cm x 22 cm) with legs extended, with screen cover on 17.9”...
  • Page 24 Vibration Agilent class B1 and MIL-PRF-28800F; class 3 random Shock Agilent class B1 and MIL-PRF-28800F; class 3 random; (operating 30g, 1/2 sine, 11 ms duration, 3 shocks/axis along major axis, total of 18 shocks) Pollution degree Normally only dry non-conductive pollution occurs.
  • Page 25: Ordering Information

    Documentation CD (PDFs of Programmer’s Reference Guide, ● ● User Guide, and Service Guide) Agilent I/O libraries suite 15.0 ● ● Localized power cord ● ● Front panel cover ● ● Note: IntuiLink Data Capture software available free on Web at www.agilent.com/find/intuilink...
  • Page 26 Product number Description N2733A Soft carrying case for 7000B Series oscilloscope N2732A Rackmount kit for 7000B Series oscilloscope GemStar 5000 Transit case with foam molding customized for InfiniiVision 7000B Series available from GemStar Mfg. www.gemstarmfg.com N2918A Evaluation kit N4865A GPIB-to-LAN adapter...
  • Page 27 Agilent Technologies Oscilloscopes Multiple form factors from 20 MHz to > 90 GHz Industry leading specs Powerful applications...