Setting The Library Scsi Id; Port 0 Address - StorageTek L180 Installation Manual

Tape library
Hide thumbs Also See for L180:
Table of Contents

Advertisement

Entering Configuration Data

Setting the Library SCSI ID

If the control path for the library is SCSI, you must set a SCSI ID for the library.
To set this value:
1. From the Main Configuration Menu press the
The Lib Config Menu will appear and the cursor will line up with
LIB SCSI I/F CONFIG.
2. Press the
menu also displays the type of SCSI interface.
3. Press the arrow buttons until the cursor underscores SCSI ID.
4. Press the
5. Use the
6. When the ID is correct, press the
Press the
• If the library SCSI ID is the only configuration value you wish to set at this
time, press the
• If you wish to set other configuration values before you reset the library,
continue with the configuration.

Port 0 Address

The Fibre Channel interface requires configuration of the library's Port 0
address for hard or soft addressing.
If you configure the library for hard addressing, you may input the Port 0
address yourself through the library's operator panel. Allowable addresses are
000d to 125d.
Note: Before you input a Port 0 address, you must first set the library's Fibre
If you configure the library for soft addressing, you are allowing the network's
software to configure the Port 0 address. For this addressing approach, you
must set the Fibre Channel hard address option to disabled.
Note: The default for the hard address option is disabled.
5-10
button. The Lib SCSI I/F Config Menu will appear. This
SELECT
LIB SCSI I/F CONFIG MENU:
LIB SCSI I/F ID: 00
SCSI TYPE: LVD (or HVD)
button. The Set Lib SCSI ID Menu will appear.
SELECT
and
arrows to change the ID.
UP
DOWN
button to abort.
MENU
button.
RESET
Channel hard address option to enabled.
Eleventh Edition
StorageTek Proprietary
button.
SELECT
button to save the changes.
SELECT
95896