Page 5
List of Pages Document Title: 9710 Library Storage Module System Assurance Guide Guide Part Number: MR0012J Initial Release Date: July 1996 Reissue J Date: December 1999 Total number of pages in this document is 86, consisting of the following: Pages...
Chapter 4: Expanded power cable table with new power cable part numbers. Corrected drawing of Centronics 50-pin connector. Added new in-country media services telephone numbers. Added note clarifying feature codes 1603 and 2016. Appendix A: Updated weight specifications. 9710 System Assurance Guide MR0012J...
Preface This guide contains information about planning, ordering, installing, and follow-up activities required during StorageTek TimberWolf 9710 Library Storage Module sales, delivery, and installation. The audience for this guide includes StorageTek marketing representatives, solutions delivery systems specialists (SDSSs), ssolutions delivery installation...
The Index assists in locating information in this publication. Trademarks StorageTek is a trademark of Storage Technology Corporation. Other features and terms used in this publication are for informational purposes only and might be trademarks of Storage Technology Corporation or other companies.
You may have access to the following additional sources of information. Customer Resource Center StorageTek’s Customer Resource Center (CRC) is an online service that provides technical information such as software publications, user documentation, maintenance fixes, and answers to frequently asked questions. The CRC is for...
Documents on CD is a compact disc that contains portable document format (PDF) files of StorageTek’s tape, library, and OPENstorage disk publications. This CD is for StorageTek employees only. Contact the Logistics Depot to order the CD or get onto the distribution list.
3. At the right side of the screen click on alphabetical. 4. Click on W for Workforce Development. 5. Scroll down and click on Workforce Development Home Page. This takes you to the StorageTek Workforce Development web page. Make your selections from here. MR0012J...
Page 18
Preface This page intentionally left blank. 9710 System Assurance Guide MR0012J...
The process is the exchange of information among the team members to ensure that no aspects of the sale, ordering, and installation are overlooked. This promotes an error-free installation and contributes to customer satisfaction. Figure 1-1. The System Assurance Overview MR0012J 9710 System Assurance Guide...
The team ensures that all aspects of the process are planned carefully and carried out efficiently. Customer and StorageTek team members jointly own and control the process. Table 1-1. Team Member Responsibilities...
Page 21
Solutions Delivery Systems • Explains available levels of software support and Specialist (SDSS) criteria for problem escalation. • Works with the customer to complete the work sheet. • Provides data migration information. MR0012J 9710 System Assurance Guide...
The following pages describe the steps in more detail. No two installations are the same; however, following this flowchart promotes a smooth system assurance process and an error-free installation. Figure 1-2. The System Assurance Process Flow 9710 System Assurance Guide MR0012J...
System Assurance Planning Meetings The purpose of the system assurance planning meetings is to: • Explain system assurance as it applies to the 9710 Library • Establish the system assurance team • Establish the responsibilities of the team members •...
If they are not correct, the system assurance team completes or corrects them. Installation The SDE installs the 9710 Library at the customer’s site. Post-installation Follow-up The following actions follow up the installation: • The Error-Free Delivery Team tracks any exceptions to the original shipment.
StorageTek Hardware and Software StorageTek Hardware and Software Support StorageTek provides the following phone numbers for hardware and software support: Call Center (Hardware) U.S.-Colorado 1.303.673.4056 U.S.-Outside Colorado (Customers) 1.800.525.0369 U.S.-Outside Colorado (SDEs) 1.800.735.2778 Software Support U.S.-Outside Colorado 1.800.678.4430 U.S.-Colorado 1.303.673.4430...
• A cartridge access port (CAP) that stores up to 14 cartridges • 9840, Digital Linear Tape (DLT), or 4890 drives installed behind the LSM right, front door. Figure 3-1. 9710 LSM with Expansion Door C60485 MR0012J 9710 System Assurance Guide...
• You may mix SCSI and Fibre Channel drives. Power Distribution Unit (PDU) The standard 9710 can support up to 10 drives, but has power connections for only six drives. When you order the 9710 mounting hardware kits for more than six drives, you must also order the PDU.
Host Interfaces The PRM card is shipped with the PDU, even though it is not part of the PDU. The card is mounted in the 9710 to provide data communication paths for the additional drives. Host Interfaces The LSM provides two host ports for AS/400 direct connections. Two internal...
Six FIPS data buses can exist on the I/O tower. Each bus in this definition includes the Data In, Data Out, Tag In, and Tag Out lines. If you are using two- bus FIPS drives, each connected at the I/O tower to two FIPS buses, then no MR0012J 9710 System Assurance Guide...
RS423 more than three FIPS drives can exist in the 9710. The remaining available drive slots can be used by SCSI drives. Twenty SCSI data buses can exist on the I/O tower: 10 in and 10 out. Twenty Fibre Channel data buses can exist on the I/O tower (with 9840 drives only): 10 in and 10 out.
SCSI Library Robotic Interface Figure 3-7. 9710 I/O Panel (Showing FIPS) Note: The 3270 control interface ports shown in Figure 3-7 on page 3-11 not presently used. One of the two SCSI control interface ports is used for the control line; the other is reserved for daisy chaining.
SCSI Library Robotic Interface Figure 3-8. 9710 I/O Panel (Showing Fibre Channel) Note: The 3270 control interface ports shown in Figure 3-8 on page 3-12 not presently used. One of the two SCSI control interface ports is used for the control line; the other is reserved for daisy chaining.
Ordering the Equipment This chapter provides the worksheets to use when ordering the 9710 LSM. The Ordering Process To order a 9710 LSM: 1. Make photocopies of the blank worksheets provided in this guide. 2. Obtain other required worksheets not provided in this guide.
Use the following paragraphs and worksheets to plan your order. For 9840 Drive information, refer to 9840 Tape Drive System Assurance Guide, MT 5003. CAUTION: You may not install 9840 drives and 4890 drives within the same LSM. 9710 System Assurance Guide MR0012J...
Hardware Order Worksheets Figure 4-1. 9710 Model/Feature Selections Note: Both feature codes 1603 and 2016 include two serial ports and do not include a SCSI card. MR0012J 9710 System Assurance Guide...
Note: If more than six drives are ordered, the customer must order the PDU. The PDU feature code includes the PDU, the appropriate power cord, the PRM card, and an additional drive-to-LSM interface cable. 9710 System Assurance Guide MR0012J...
Hardware Order Worksheets 4890 Drives Figure 4-5 lists the 4890 drive feature numbers. Figure 4-5. 4890 Drive Feature Selections CAUTION: You may not install 9840 drives and 4890 drives within the same LSM. 9710 System Assurance Guide MR0012J...
15 A, 2.5 m (8.2 ft), 16 AWG SJT cord. For optional PDU Serial Cables, 9710 to Host If the robot is controlled by a serial RS423 connection, the 9710-end of the cables requires a female DB9 connector. MR0012J 9710 System Assurance Guide...
SCSI Cabling The following pages contain SCSI cable and adapter information. Cable Restriction Maximum allowed cable lengths (including the lengths already inside the 9710) are: • Single-ended: up to 6 m (20 ft) for up to 5 mega transfers per second •...
Cable Length Subtraction When considering the length of an external SCSI interface bus, you must subtract the length of bus already inside the 9710 from the maximum allowed cable length. The individual cable measurements inside the 9710 are: • From I/O tower to drive: 1.2 m (4 ft) •...
Page 54
Calculated for a control interface daisy chain cable of 0.5 m (18 in.). Add 0.8 m (2.5 ft) for a 1.2 m (4 ft) cable, and 1.1 m (4.5 ft) for a 1.8 m (6 ft) cable. 4-14 9710 System Assurance Guide MR0012J...
9710 to Host There are many external SCSI cables, depending on the platform. These cables are available through StorageTek. These are “standard” and will fit most applications for data and the control path. Table 4-5. SCSI Cables 9710 to Host...
SCSI Cabling PRS Card When installing a PRS in the 9710, the cables listed below are required from the PRC to the drives. Table 4-8. PRS Card Cables Drive Location Cable Length Part Number Quantity 1220 mm (48 in.) 310292101 ________ 1220 mm (48 in.)
Table 4-11. SCSI Cables and Adapters for Sun Sparc Workstation Description Part Number Quantity StorageTek 3 m (10 ft) cable to attach the 9710 10083522 ________ directly to the Sun/Sparc workstation motherboard, or to a station with SBE/S (fast/narrow, differential) or RSBE/S (fast/narrow, single-ended) Standard 68–68-pin SCSI cable.
Table 4-12. SCSI Cables and Adapters for RS/6000 and Bull DPX/20 Description Part Number Quantity StorageTek 3 m (10 ft) cable to attach the 9710 10083522 ________ directly to the Sun/Sparc workstation motherboard, or to a station with IBM RISC System/6000 with...
IOP and FIPS cable types. Cabling configurations are shown in Figure 4-7. Part numbers are listed below. The flagged 4-digit IBM part numbers must be ordered from IBM. Figure 4-7. FIPS AS/400 Cabling Configurations 4-24 9710 System Assurance Guide MR0012J...
________ Bus and tag cable pair 61 m (20 ft) 305436200 ________ Bus and tag cable pair 91.44 m (300 ft) 305436300 ________ Bus and tag cable pair 122 m (400 ft) 305436400 ________ MR0012J 9710 System Assurance Guide 4-25...
________ Terminator, FIPS, Tag 10041794 ________ FIPS Drive to I/O The FIPS cable is listed below. Table 4-20. FIPS Cables Description Part Number Quantity FIPS cable assembly from drive to I/O panel 310259302 ________ 4-26 9710 System Assurance Guide MR0012J...
One StorageTek Drive Louisville, CO 80028-4350 Voice: 1-303-673-5513 Table 4-23. In-Country Media Supply Services (Sheet 1 of 2) Region Country Telephone Number United States 1-800-905-8502 North Canada 1-800-668-1843 extension 605 America Mexico 525 258 8000 4-28 9710 System Assurance Guide MR0012J...
Page 69
Brazil 55 11 5185 2850 Japan 3 3746 9824 Singapore 65 774 9248 World Kuala Lumpur 60 3 233 6102 China 86 10 6841 2211 Thailand 662 656 8873 Hong Kong 852 8200 0791 MR0012J 9710 System Assurance Guide 4-29...
Page 70
Cartridge Tapes and Labels This page intentionally left blank. 4-30 9710 System Assurance Guide MR0012J...
Yes/No Fire Suppression System Ensure customer is aware that StorageTek does not supply fire suppression systems. Any fire suppression system for the 9710 is the customers’ responsibility. Hardware Support Services StorageTek offers an exclusive remote service to customers which is available 24 hours a day 7 days a week if a problem with the equipment occurs.
Page 73
RJ-45 100 ft MARS/UUT interconnect 410828910 150 ft MARS/UUT interconnect 410828915 200 ft MARS/UUT interconnect 410828920 250 ft MARS/UUT interconnect 410828925 Modem/ 4 ft modem to MARS 4895 MARS interconnect (DB-25 to DB-9) Interconnect Cable MR0012J 9710 System Assurance Guide...
Page 74
Hardware Support Services This page intentionally left blank. 9710 System Assurance Guide MR0012J...
The following table lists the dimensions and weight of the LSM. Refer to your drive publications for the weight of the drives and cartridges and add the weights to the weights in the table. Table A-1. 9710 Dimensions and Weights Height 1830 mm (72 in.) Width with covers 1490 mm (59 in.)
29.2°C (84.5°F) Storage 35°C (95°F) Shipping 35°C (95°F) Altitude Operating 0 to 3.05 km (0 to 10,000 ft) Storage 0 to 3.05 km (0 to 10,000 ft) Shipping 0 to 15.24 km (0 to 50,000 ft) 9710 System Assurance Guide MR0012J...
Figure A-1. 9710 Layout and Floor Space Requirements SEE NOTE 1 POWER CABLE CUTOUT 153.26 148.82 (60.34) (58.59) 218.92 (86.19) LSM BASIC UNIT SERVICE AREA REQUIREMENTS 218.92 (86.19) SEE NOTE 1 15.24 (6) 60.96 (24) FIPS CABLES CUTOUT (SEE NOTE 2) 153.57...
PDU 120 VAC domestic wall NEMA 5-15R, supplied by client receptacle International plugs and receptacles May be supplied by client according to for 9710 and, if applicable, for PDU local electrical codes. See power specifications below. See Table 4-1 on page 4-9.
Page 79
257 BTU/hr Note: Up to six drives take power from the 9710. Four additional drives take power from the PDU box. Power ratings for the 9710, and (separately) for the PDU, are figured by also adding the number of drives connected to each. The PDU box by itself has zero load.
Page 80
This page intentionally left blank. 9710 System Assurance Guide MR0012J...
Atlanta Shared Services Center, 4-2 robotics control, internal, 4-18 cartridge and label orders, 4-28 SCSI Orders Management, 4-2 9710 to host, 4-15 fire suppression, 5-2 for AS/400 path, 4-19, 4-25 for RS/6000 and Bull, 4-21 for Sun, 4-20 Hardware Support Services, 5-2 Sequent, 4-23 host, server indirect.
Page 83
’ EADER OMMENT Manual Name: ___________________________________________ Manual PN: _______________ Please check or fill in the items; adding explanations/comments in the space provided. Which of the following terms best describes your job? Field Engineer Manager Programmer Systems Analyst Engineer Mathematician Sales Representative Systems Engineer Instructor Operator...
Page 84
FIRST CLASS PERMIT NO. 2 LOUISVILLE, CO U.S.A. POSTAGE WILL BE PAID BY ADDRESSEE NEARLINE INFORMATION DEVELOPMENT MS 2201 STORAGE TECHNOLOGY CORPORATION ONE STORAGETEK DRIVE LOUISVILLE CO 80027-9984 FOLD HERE AND TAPE DO NOT STAPLE FOLD HERE AND TAPE If you would like a reply, please print:...
Need help?
Do you have a question about the 9710 and is the answer not in the manual?
Questions and answers