Reporting SCSI Drive Information

Before you configure a drive, take note of its SCSI system address and whether
it is "on bus" or "off bus." Record this information in
The first column in the table lists the logical drive number assigned to each
drive. The library assigns this number during an IPL. The uppermost drive
within the drive column is designated as "0," the next is "1," and so forth.
Note: These drive numbers are only for the library-to-drive communication.

SCSI ID

You must set a SCSI identifier for each drive installed in the library.

On Bus or Off Bus

This entry indicates whether the drive is on the same interface path (on bus) as
the library or on a separate bus (off bus).

Display Information

Figure 5-9
Information Menu allows you to adjust the contrast and backlight on the display
screen. These screen characteristics are saved in non-volatile memory.

Figure 5-9. Display Information Menu

DISPLAY INFO MENU:
CONTRAST: 09
DEFAULT = 16
BACKLIGHT: 128
DEFAULT = 128
RESTORE DEFAULTS
MENU TO EXIT
To change the contrast and backlight (or brightness) of the operator panel:
1. At the Main Configuration Menu, press the
cursor underscores DISPLAY INFO.
2. Press the
3. Use the arrow buttons to line up with the desired screen characteristic:
CONTRAST or BACKLIGHT. An editing screen will appear.
95896
shows an example of the display information screen. The Display
button. The Display Info Menu will appear.
SELECT
Eleventh Edition
StorageTek Proprietary
Entering Configuration Data
Table 5-2 on page
or
arrows until the
UP
DOWN
5-3.
5-25