9. Double click on
The SEND FILE box will appear, showing the pathname and the protocol
chosen. Protocol should be set to Z-MODEM.
10. Click on
The status window for the transfer will appear.
CAUTION:
Equipment Damage: Do not attempt to perform any operations on the PC
or library until the operator panel displays DOWNLOAD COMPLETE.
Damage to the MPC card may occur if you do not wait for the process to
complete.
If, for any reason, the download does not complete successfully, make
sure that the xon/xoff setting is valid for the current Hyperterminal
session, then retry the download immediately.
Do not reset, cycle power, or open a library access door.
11. Wait for the following prompt: Reboot 'yes'?
12. Respond with 'yes' to reboot the machine and activate the firmware. Or
you may power cycle or IPL the library to activate the firmware.
Notes:
• If you do not reboot, power cycle, or IPL the library to activate the new
firmware, the old firmware version will remain active. When the next
reboot, power cycle, or IPL occurs, the new firmware will become active.
• When the reboot is complete, verify that the version is correctly listed on
the operator panel.
• The fault symptom code (FSC) dictionary is also contained on the firmware
diskette or CD. The file name is "fsc" and, when proper security
safeguards are followed, this file may also be copied to a file on your
personal computer.
B-6
.
release.prm
SEND
.
Eleventh Edition
StorageTek Proprietary
95896