Entering Configuration Data
-
-
4. When your choice is highlighted:
• Press the
• Press the
5. Continue these steps until all drives are configured.

Fibre Channel Drive Entries (T9840)

To configure a T9840 drive:
1. The drive must have firmware version 1.24 or higher. Check the drive's
firmware version, by selecting DRIVE INFO from the Main Menu.

Figure 5-8. Drive Information Menu

DRIVE INFORMATION MENU:
VENDOR: STK
TYPE: 9840
STATUS: 00 EMPTY
SERIAL NUMBER:
XXXXXXXXX
INTERFACE TYPE:
FIBRE I/F
CODE VERSION:
x.xx
2. Refer to the T9840/T9940 Tape Drive Installation or Service Reference
Manual for information about T9840/T9940 drive configuration options and
instructions.

Drive Configurations

After you have completed the drive configuration:
• If you have already configured the library's SCSI ID or Port 0 address,
network entries, and you are planning to exit the Main Configuration Menu,
press the
• If you have not changed the library's configuration and you are not setting
other configuration values, press the
• If you wish to set other configuration values, continue with
Information" on page
5-24
If you select enabled, the hard address will be set to 0.
If you select disabled, the address will arbitrate through the channel.
button to save the changes.
SELECT
button to abort.
MENU
button.
RESET
5-25.