Interface Connections

SCSI Bus Precautions

You must use caution when connecting LVD or HVD interfaces. Equipment
damage or bus-disabling situations may arise if the two types of interfaces are
intermixed.
CAUTION:
Potential equipment damage: The single-ended, LVD, and HVD SCSI
alternatives are not compatible and cannot be mixed on the same SCSI
bus.

Table 1-2. SCSI Device/Bus Types: Precautions

If you plug this
device type ...
Single-ended
(SE) device
LVD device
HVD device

Fibre Channel

The following Fibre Channel cable and connector specifications are supported:

Table 1-3. Fibre Channel Cables and Connectors

Distance
Meters
Feet
2–300
6.5–985
2–500
6.5–1640
1-10
into a Single-ended
(SE) Bus Type ...
No effect. This is a
proper connection.
The LVD device will
run in SE mode.
The HVD device will
be disabled.
Multimode
FC-0 Code
100-M6-SN-I
62.5 µm
100-M5-SN-I
Eleventh Edition
StorageTek Proprietary
into an LVD
Bus Type ...
The entire bus will run
in SE mode (with all
SE restrictions).
No effect. This is a
proper connection.
The LVD bus and all
LVD devices will be
disabled (potential
damage to LVD
devices)
Cable
Type
Shortwave laser
w/o OFC
50 µm
into an HVD
Bus Type ...
The HVD bus will be
disabled.
The LVD device will
be disabled (potential
damage to the device).
No effect. This is a
proper connection.
Connector
Duplex SC or LC
95896