Preparing the Library Location
Figure 2-1. Service Area Requirements and Cable Access Locations (C67043)
4
1. 2.6 m (8.5 ft) (both front and rear doors open)
2. 0.8 m (2.6 ft) (front and rack door open)
3. When positioning the library, consider that a minimum of 1.0 m (3.3 ft) might be necessary for
removing the side panel during service calls.
Note:
These statements apply to side area clearance:
For normal operation, allow a minimum of 51 mm (2 in.) of space on each side for air flow.
Side cover removal is not required for service; removal is optional. Service can be performed
with front and rear access only.
4. Cable access locations (through the floor of the library) in the rear of the library
2-4
1
Eleventh Edition
StorageTek Proprietary
2
3
C67043
95896