Operator Panel Entry; Library Entries; Setting The Library's Scsi Id - StorageTek L700e Operator's Manual

Tape library
Table of Contents

Advertisement

Entering Configuration Data
You may enter all configuration data through the operator panel. See
Panel Entry"
installed the Horizon L Series Library Monitor, you also can enter some
configuration data through a workstation or a PC that is running a Netscape or
Microsoft browser. For more information, access the online help files for the
Horizon L Series Library Monitor.

Operator Panel Entry

Entering configuration data through the operator panel prepares the library for
operation. For a detailed description of the operator panel, see
Panel" on page

Library Entries

Four entries are required for a library—other entries will vary with your options:
• Library SCSI ID or Fibre Channel Port 0 address
• Drive Fast Load enable/disable
• Date
• Time
Note: The procedures below assume that you will make all entries during one,

Setting the Library's SCSI ID

If the control path for the library is SCSI, you must enter the library's SCSI ID at
the operator panel. Set the library SCSI ID from the Lib SCSI I/F Config Menu.
Note: The information below explains special circumstances for selecting a
3-4
(in the following section) for specific instructions. If you have
2-1.
operator panel entry session. Each item is saved as it is changed, except
for the library's SCSI ID or Fibre Channel Port 0 address: to save a
revised library SCSI ID, you must reset the library by pressing the
button.
RESET
SCSI ID (address) for the library:
1. When configuring the library to a Unix-based workstation,
StorageTek recommends that you use a dedicated SCSI client host
bus adapter (HBA):
-
For wide SCSI adapters, you may assign any address from 0 to
14 for the library.
-
For narrow SCSI adapters, the range of addresses is 0 to 6.
2. If you choose to use the embedded system bus on the SPARC
station, select address 6, 5, 2, or 0 for the library; the remaining
targets are reserved for Sun peripherals.
3. For IBM RISC System/6000 machines, available addresses on the
embedded system bus are 6, 5, 3, and 2.
Tenth Edition
"Operator
"Operator
95845