General System Information
46
G8264CS Command Reference for ENOS 8.4
The following command displays system information:
show sysinfo
Command mode: All
System Information at 12:27:46 Wed May 27, 2015
Time zone: No timezone configured
Daylight Savings Time Status: Disabled
Lenovo RackSwitch G8264CS
Switch has been up for 0 days, 21 hours, 21 minutes and 44 seconds.
Last boot: 15:07:19 Tue May 26, 2015 (reset from console)
MAC address: 74:99:75:75:63:00 IP (If 1) address: 0.0.0.0
Management Port MAC Address: 74:99:75:75:63:fe
Management Port IP Address (if 128): 10.241.37.200
Hardware Revision: 0
Hardware Part No: BAC0011000
Switch Serial No: Y250CM2C9009
Manufacturing date: 12/50
MTM Value: 7159HCM
ESN: MM05941
Software Version 8.4.1.0 (FLASH image1), factory default configuration.
Boot kernel version 8.4.1.0
USB Boot: disabled
Temperature Mezzanine : 32 C
Temperature CPU Local : 38 C
Temperature Mother Top : 31 C
Temperature Mother Bottom : 33 C
Temperature Switch Asic Max : 43 C
Temperature FC Module Max : 59 C
System Warning at 86 C / Shutdown at 95 C / Set Point is 76 C
Fan 1 Module 1: 7468rpm 25pwm( 9%) FrontToBack
Fan 2 Module 1: 3163rpm 25pwm( 9%) FrontToBack
Fan 3 Module 2: 7346rpm 25pwm( 9%) FrontToBack
Fan 4 Module 2: 3362rpm 25pwm( 9%) FrontToBack
Fan 5 Module 3: 7479rpm 25pwm( 9%) FrontToBack
Fan 6 Module 3: 3126rpm 25pwm( 9%) FrontToBack
Fan 7 Module 4: 7336rpm 25pwm( 9%) FrontToBack
Fan 8 Module 4: 3174rpm 25pwm( 9%) FrontToBack
System Fan Airflow: FrontToBack
Power Supply 1: FrontToBack [43X3311]
Power Supply 2: FrontToBack []
FCM Faults: None
Power Faults: PS2I2C PS2Vin PS2Pwr
Fan Faults: None
Service Faults: TooFewPS