Fip Snooping Fcoe Forwarder Information - Lenovo RackSwitch G8264CS Cli Command Reference

Iscli industry standard cli for lenovo enterprise network operating system 8.4
Hide thumbs Also See for RackSwitch G8264CS:
Table of Contents

Advertisement

FIP Snooping FCoE Forwarder Information
184
G8264CS Command Reference for ENOS 8.4
The following command shows FCoE forwarder (FCF) information that has been 
learned (detected) by the switch:
show fcoe fips fcf
Command mode: All  
Total number of FCFs detected: 0
The following command displays FIP Snooping information for the selected port:
show fcoe fips port <port alias or number> information
Command mode: All  
FIP Snooping on port INT2:
This port has been configured to automatically detect FCF.
 It has currently detected to have 0 FCF connecting to it.
FIPS ACLs configured on this port:
SMAC 00:c0:dd:13:9b:6f, action deny.
SMAC 00:c0:dd:13:9b:70, action deny.
SMAC 00:c0:dd:13:9b:6d, action deny.
SMAC 00:c0:dd:13:9b:6e, action deny.
DMAC 00:c0:dd:13:9b:6f, ethertype 0x8914, action permit.
DMAC 00:c0:dd:13:9b:70, ethertype 0x8914, action permit.
DMAC 00:c0:dd:13:9b:6d, ethertype 0x8914, action permit.
DMAC 00:c0:dd:13:9b:6e, ethertype 0x8914, action permit.
SMAC 0e:fc:00:01:0a:00, DMAC 00:c0:dd:13:9b:6d, ethertype 0x8906, vlan 
1002, action permit.
DMAC 01:10:18:01:00:01, Ethertype 0x8914, action permit.
DMAC 01:10:18:01:00:02, Ethertype 0x8914, action permit.
Ethertype 0x8914, action deny.
Ethertype 0x8906, action deny.
SMAC 0e:fc:00:00:00:00, SMAC mask ff:ff:ff:00:00:00, action deny.
FIP Snooping port information includes the following:
Fibre Channel Forwarding (FCF) mode
Number of FCF links connected to the port
List of FIP Snooping ACLs assigned to the port