19 SPI
19.7 Control Register Details
Address
0x4320
SPI_ST
SPI Status Register
0x4322
SPI_TXD
SPI Transmit Data Register
0x4324
SPI_RXD
SPI Receive Data Register
0x4326
SPI_CTL
SPI Control Register
The SPI registers are described in detail below. These are 16-bit registers.
Note: • When data is written to the registers, the "Reserved" bits must always be written as 0 and
not 1.
• Always use 16-bit access commands to read and write to/from the SPI register. 32-bit and
8-bit access commands cannot be used to read and write to/from the SPI register.
242
Table 19.7.1: SPI register list
Register name
EPSON
Function
Transfer, buffer status display
Transmission data
Received data
SPI mode and data transfer permission setting
S1C17001 TECHNICAL MANUAL