The stopwatch timer uses the 256 Hz clock output by the OSC module as the operation clock.
The OSC module generates this operation clock by dividing the OSC1 clock into 1/128, resulting in a frequency of
256 Hz when the OSC1 clock frequency is 32.768 kHz. The frequency described in this section will vary accord-
ingly for other OSC1 clock frequencies.
The OSC module does not include a 256 Hz clock output control bit. The 256 Hz clock is normally fed to the stop-
watch timer when the OSC1 oscillation is on.
For detailed information on OSC1 oscillator circuit control, refer to "7 Oscillator Circuit (OSC)."