Omron SYSMAC CS Series Operation Manual page 813

Programmable controllers
Hide thumbs Also See for SYSMAC CS Series:
Table of Contents

Advertisement

Restrictions in Using C200H Special I/O Units
1,2,3...
Special I/O Units in Groups I and III
Area/Address specifications in CS-series CPU Unit
Area
CIO
0000 to 0255
0256 to 0999
CIO
1000 to 1063
CIO
1064 to 6143
Work
W000 to W511
Auxiliary
A000 to A959
Holding
H000 to H099
H100
H101
H102 to H127
H128 to H511
Timer
T0000 to T0511
T0512 to Y4095
Counter
C0000 to C4095
DM
D00000 to D00999
D06656 to D19999
D20000 to D20999
D21000 to D32767
EM
E0_00000 to E0_32767
E1_00000 to EC_32767
Restrictions in Programming C200H Special I/O Units for the CS Series
(Groups I to IV)
There following restrictions in area and address specifications exist in pro-
gramming inside C200H Special I/O Units (i.e., ASCII Unit) or in specifying
C200H Special I/O Unit allocations for the CS-series CPU Unit.
1. CIO 0256 to CIO 0999 cannot be specified for Units in Group I or III, CIO
0281, 0512 to CIO 0999 cannot be specified for Units in Group II or IV, and
CIO 1064 to CIO 6143 cannot be specified.
2. Addresses in the Work Area (W000 to W511) cannot be specified.
3. H101 and H128 to H511 cannot be specified, and H100, H102 to H127
must be specified using AR 00, AR02 to AR 27.
4. Timers T0512 to T4095 cannot be specified.
5. Counters (C0000 to C4095) cannot be specified.
6. D01000 to D19999 and D21000 to D32767 in Group I or III D06656 to
D32767 in Group II or IV cannot be specified.
Note If D1000 to D1999 are specified in a C200H Special I/O Unit for data
transfer, the CS Series will interpret them as D20000 to D20999. Do
not use D1000 to D1999.
7. E0_06144 to E0_32767 (bank 0) and E@_00000 to E@_32767 in all banks
except bank 0 cannot be specified.
Addresses
Areas/Addresses to use in C200H Special I/O Unit
Area
IR
000 to 255
Not addressable.
LR
LR 00 to LR 63
IR
Not addressable.
None
---
None
---
HR
HR 00 to HR 99
AR
AR 00
AR
Not addressable.
AR
AR 02 to AR 27
None
---
Timer/Counter
TIM/CNT 000 to TIM/CNT 511
Not addressable.
Not addressable.
DM
DM0000 to DM 0999
Not addressable.
DM1000 to DM1999
Not addressable.
None
---
---
Appendix F
Address
775