PLC Setup
Start Code/End Code
Programming
Console address
Word
Bit(s)
+164
8 to 15
00 to FF
Default: 00
0 to 7
00 to FF
Default: 00
+165
12
0: None
1: Code in 164
Default: 0
8 to 9
0: None
1: Code in 164
2: CR+LF
Default: 0
0 to 7
00: 256 bytes
01 to FF:
1 to 255 bytes
Default: 00
Serial Gateway Settings
Communications Settings
Programming
Console address
Word
Bit(s)
+160
15
0: Default (stan-
dard)*
1: PLC Setup (cus-
tom)
Default: 0
Mode: Communications Mode
Programming
Console address
Word
Bit(s)
+160
8 to 11
9: Serial Gateway
Default: 0
+160
8 to 11
0: Host Link
5: Host Link
Default: 0
Settings
Start code: Set this start code only when the
start code is enabled (1) in bits 12 to 15 of
165.
End code: Set this end code only when the
end code is enabled (1) in bits 8 to 11 of
165.
Start code setting:
A setting of 1 enables the start code in 164
bits 8 to 15.
End code setting:
With a setting of 0, the amount of data being
received must be specified. A setting of 1
enables the end code in bits 0 to 7 of 164. A
setting of 2 enables an end code of CR+LF.
Set the data length to be sent and received
with no-protocol communications. The end
code and start code are not included in the
data length.
Set this value only when the end code set-
ting in bits 8 to 11 of 165 is "0: None."
This setting can be used to change the
amount of data that can be transferred at
one time by TXD(236) or RXD(235). The
default setting is the maximum value of 256
bytes.
Settings
*The default settings are for a baud rate of
9,600 bps.
Settings
This setting determines whether the com-
munications mode for the RS-232C port
port.
The peripheral bus mode is used for all Pro-
gramming Devices except for Programming
Consoles.
This setting determines whether the com-
munications mode for the RS-232C port.
(Host Link can be used when specified to
either 0 or 5 hex.)
Function
Function
Function
Section 7-1
Related
When set-
flags and
ting is read
words
by CPU Unit
A61902
At the next
(RS-232C
cycle.
Port Settings
(Also can be
Changing
changed with
Flag)
STUP (237).)
Related
New set-
flags and
ting's effec-
words
tiveness
A61901
Takes effect
(RS-232C
the next
Port Settings
cycle.
Changing
(Also can be
Flag)
changed with
STUP (237).)
Related
New set-
flags and
ting's effec-
words
tiveness
A61901 (RS-
Takes effect
232C Port
the next
Settings
cycle.
Changing
(Also can be
Flag)
changed with
STUP (237).)
A61901 (RS-
Takes effect
232C Port
the next
Settings
cycle.
Changing
(Also can be
Flag)
changed with
STUP (237).)
357