Omron SYSMAC CS Series Operation Manual page 783

Programmable controllers
Hide thumbs Also See for SYSMAC CS Series:
Table of Contents

Advertisement

Auxiliary Area
Addresses
Name
Word
Bit
A732 to
Power ON
A734
Clock
Data 5
(See
note.)
A735 to
Power ON
A737
Clock
Data 6
(See
note.)
A738 to
Power ON
A740
Clock
Data 7
(See
note.)
A741 to
Power ON
A743
Clock
Data 8
(See
note.)
A744 to
Power ON
A746
Clock
Data 9
(See
note.)
A747 to
Power ON
A749
Clock
Data 10
(See
note.)
Note Supported by unit version 3.0 or later.
Function
These words contain the time at which
the power was turned ON four times
before the startup time stored in words
A510 to A511.
A73200 to A73207: Seconds (00 to 59)
A73208 to A73215: Minutes (00 to 59)
A73300 to A73307: Hour (00 to 23)
A73308 to A73315: Day of month (00 to
31)
A73400 to A73407: Month (01 to 12)
A73408 to A73415: Year (00 to 99)
These words contain the time at which
the power was turned ON five times
before the startup time stored in words
A510 to A511.
A73500 to A73507: Seconds (00 to 59)
A73508 to A73515: Minutes (00 to 59)
A73600 to A73607: Hour (00 to 23)
A73608 to A73615: Day of month (00 to
31)
A73700 to A73707: Month (01 to 12)
A73708 to A73715: Year (00 to 99)
These words contain the time at which
the power was turned ON six times
before the startup time stored in words
A510 to A511.
A73800 to A73807: Seconds (00 to 59)
A73808 to A73815: Minutes (00 to 59)
A73900 to A73907: Hour (00 to 23)
A73908 to A73915: Day of month (00 to
31)
A74000 to A74007: Month (01 to 12)
A74008 to A74015: Year (00 to 99)
These words contain the time at which
the power was turned ON seven times
before the startup time stored in words
A510 to A511.
A74100 to A74107: Seconds (00 to 59)
A74108 to A74115: Minutes (00 to 59)
A74200 to A74207: Hour (00 to 23)
A74208 to A74215: Day of month (00 to
31)
A74300 to A74307: Month (01 to 12)
A74308 to A74315: Year (00 to 99)
These words contain the time at which
the power was turned ON eight times
before the startup time stored in words
A510 to A511.
A74400 to A74407: Seconds (00 to 59)
A74408 to A74415: Minutes (00 to 59)
A74500 to A74507: Hour (00 to 23)
A74508 to A74515: Day of month (00 to
31)
A74600 to A74607: Month (01 to 12)
A74608 to A74615: Year (00 to 99)
These words contain the time at which
the power was turned ON nine times
before the startup time stored in words
A510 to A511.
A74700 to A74707: Seconds (00 to 59)
A74708 to A74715: Minutes (00 to 59)
A74800 to A74807: Hour (00 to 23)
A74808 to A74815: Day of month (00 to
31)
A74900 to A74907: Month (01 to 12)
A74908 to A74915: Year (00 to 99)
Settings
Status
Status at
after
mode
change
See at left.
Retained Retained Written when power is
See at left.
Retained Retained Written when power is
See at left.
Retained Retained Written when power is
See at left.
Retained Retained Written when power is
See at left.
Retained Retained Written when power is
See at left.
Retained Retained Written when power is
Appendix B
Write timing/
startup
Related Flags,
Settings
turned ON.
turned ON.
turned ON.
turned ON.
turned ON.
turned ON.
745