Auxiliary Area
Address
Name
Words
Bits
A344
All
EM File
Memory
Starting
Bank
A345
A34500
FB Pro-
gram Data
Flag
A34501
Program
Index File
Flag
A34502
Comment
File Flag
A34503
Symbol
Table File
Flag
A346
All
Number of
and
Remaining
A347
Words to
Transfer
A351 to
All
Calen-
A354
dar/Clock
Area
A35100
to
A35107
A35108
to
A35115
A35200
to
A35207
A35208
to
A35215
A35300
to
A35307
A35308
to
A35315
A35400
to
A35407
A355
A35500
Inner Board
to
Monitoring
A35915
Area
Function
Contains the starting bank number of EM file memory
(bank number of the first formatted bank). All EM
banks from this starting bank to the last bank in EM
are formatted for use as file memory.
To convert the EM Area for use as file memory, first set
the PLC Setup's EM File Memory Function setting to
1, set the PLC Setup's EM File Memory Starting Bank
setting, and then format the EM Area from a Program-
ming Device
The PLC Setup's EM file memory settings won't agree
with the actual settings unless the EM Area is format-
ted after the PLC Setup's EM file memory settings
have been changed. In that case, the actual settings
can be determined with this word.
Turns ON if the FB program memory contains FB
program data.
Turns ON when the comment memory contains a
program index file.
Turns ON when the comment memory contains a
comment file.
Turns ON when the comment memory contains a
symbol table file.
These words contain the 8-digit hexadecimal number
of words remaining to be transferred by FREAD(700)
or FWRIT(701). When one of these instructions is exe-
cuted, the number of words to be transferred is written
to A346 and A347.
While the data is being transferred, the value in these
words is decremented.
A326 contains the rightmost 4-digits and A347 con-
tains the leftmost 4-digits.
Check the content of these words to determine
whether or not the planned number of words have
been transferred successfully.
These words contain the CPU Unit's internal clock
data in BCD. The clock can be set from a Program-
ming Device such as a Programming Console, with the
DATE(735) instruction, or with a FINS command
(CLOCK WRITE, 0702).
Seconds (00 to 59) (BCD)
Minutes (00 to 59) (BCD)
Hours (00 to 23) (BCD)
Day of the month (01 to 31) (BCD)
Month (01 to 12) (BCD)
Year (00 to 99) (BCD)
Day of the week (00 to 06) (BCD)
00: Sunday, 01: Monday, 02: Tuesday,
03: Wednesday, 04: Thursday,
05: Friday, 06: Saturday
The function of these words is defined by the Inner
Board.
Appendix B
Status
Status at
Write timing/
after
startup
Related flags,
mode
change
Retained Retained Written when EM file
formatting is per-
formed
PLC Setup (EM File
Memory Function set-
ting and EM File Mem-
ory Starting Bank
setting)
Retained Retained When program is
downloaded
Retained Cleared
Written as FREAD or
FWRIT is being exe-
cuted.
Decremented as data
is actually transferred.
Retained Retained Written every cycle
Deter-
Deter-
---
mined by
mined by
Inner
Inner
Board
Board
settings
723