File Memory

3-1-4

Dimensions

3-2

File Memory

File memory
Memory Card
EM file memory
Bank 0
Bank n
EM file
memory
Bank C
Comment memory
(CS/CJ-series CPU
Units with unit version
3.0 or later only)
172
CS1H-CPU@@-EV1 and CS1G-CPU@@-EV1
CS1H-CPU@@H, CS1G-CPU@@H
For CS-series CPU Units, the Memory Card and a specified part of the EM
Area can be used to store files. All user programs, the I/O Memory Area, and
the Parameter Area can be stored as files.
Memory type
Flash mem-
30 Mbytes
ory
64 Mbytes
128 Mbytes
RAM
The maximum capacity of the CPU
Unit's EM Area (e.g., the maximum
capacity for a CPU67 is 832 Kbytes)
CPU Unit's
Comment files
internal flash
CPU66H/67H: 128 Kbytes
memory
Other CPU Units: 64 Kbytes
Program index files
CPU66H/67H: 128 Kbytes
Other CPU Units: 64 Kbytes
Symbol table files
CPU45H/65H66H/67H: 128 Kbytes
Other CPU Units: 64 Kbytes
Note
1. A Memory Card can be written up to approximately 100,000 times. (Each
write operation to the Memory Card must be counted regardless of the size
of the write.) Be particularly careful not to exceed the life of the Memory
Card when writing to it from the ladder program.
2. The HMC-AP001 Memory Card Adapter is shown below.
3. The HMC-EF183 cannot be used with all CPU Units. Before ordering, refer
to Precaution on Applicable Units on page 173.
Memory capacity
Section 3-2
Model/Contents
HMC-EF372
HMC-EF672
HMC-EF183 (See note 3.)
The specified bank (set in the PLC
Setup) to the last bank of the EM Area
in the I/O Memory.
CX-Programmer rung comments and
other comments
CX-Programmer section names, sec-
tion comments, and program com-
ments
CX-Programmer global symbol tables,
local symbol tables, and settings for
automatically allocated areas.