Omron SYSMAC CS Series Operation Manual page 488

Programmable controllers
Hide thumbs Also See for SYSMAC CS Series:
Table of Contents

Advertisement

Auxiliary Area
Operation Start and End Times
Name
Operation Start Time
Operation End Time
Power Supply ON/OFF Time Information
Name
Startup Time
Power Interruption Time
Number of Power
Interruptions
Total Power ON Time
Power ON Clock Data 1 (See
note.)
450
Address
A515 to
The time that operation started as a result of changing the
A517
operating mode to RUN or MONITOR mode is stored here in
BCD.
A51500 to A51507: Seconds (00 to 59)
A51508 to A51515: Minutes (00 to 59)
A51600 to A51607: Hour (00 to 23)
A51608 to A51615: Day of month (01 to 31)
A51700 to A51707: Month (01 to 12)
A51708 to A51715: Year (00 to 99)
Note: The previous start time is stored after turning ON the
power supply until operation is started.
A518 to
The time that operation stopped as a result of changing the
A520
operating mode to PROGRAM mode is stored here in BCD.
A51800 to A51807: Seconds (00 to 59)
A51808 to A51815: Minutes (00 to 59)
A51900 to A51907: Hour (00 to 23)
A51908 to A51915: Day of month (01 to 31)
A52000 to A52007: Month (01 to 12)
A52008 to A52015: Year (00 to 99)
Note: If an error occurs in operation, the time of the error will
be stored. If the operating mode is then changed to PRO-
GRAM mode, the time that PROGRAM mode was entered
will be stored.
Address
A510 and
These words contain the time (in BCD) at which the power
A511
was turned ON. The contents are updated every time that
the power is turned ON.
A51000 to A51007: Seconds (00 to 59)
A51008 to A51015: Minutes (00 to 59)
A51100 to A51107: Hour (00 to 23)
A51108 to A51115: Day of the month (01 to 31)
A512 and
These words contain the time (in BCD) at which the power
A513
was interrupted. The contents are updated every time that
the power is interrupted.
A51200 to A51207: Seconds (00 to 59)
A51208 to A51215: Minutes (00 to 59)
A51300 to A51307: Hour (00 to 23)
A51308 to A51315: Day of month (01 to 31)
A514
Contains the number of times (in binary) that power has
been interrupted since the power was first turned on. To
reset this value, overwrite the current value with 0000.
A523
Contains the total time (in binary) that the PLC has been on
in 10-hour units. The data is stored is updated every 10
hours. To reset this value, overwrite the current value with
0000.
A720 to
These words contain the startup date/time (the same time
A722
as the startup time stored in words A510 to A511 as well as
the month and year information) for the last time that power
was turned ON. The data is BCD.
A72000 to A72007: Seconds (00 to 59)
A72008 to A72015: Minutes (00 to 59)
A72100 to A72107: Hour (00 to 23)
A72108 to A72115: Day of month (01 to 31)
A72200 to A72207: Month (01 to 12)
A72208 to A72215: Year (00 to 99)
Description
Description
Section 9-16
Access
Read/write
Read/write
Access
Read/write
Read/write
Read/write
Read/write
Read/write