Units
2-4-3

CS-series CPU Bus Units

Name
Specifications
Controller
Wired
Link Units
Optical ring,
H-PCF cable
Optical ring,
GI cable
SYSMAC
Coaxial
LINK Units
Optical
Serial Com-
Two RS-232C Ports
munications
Unit
Two RS-422A/ 485 Ports
Ethernet
10Base-5
Unit
100Base-TX (Can be used
as 10Base-T.)
FL-net Unit
100Base-TX cyclic transmis-
sions and message transmis-
sions
DeviceNet
DeviceNet remote I/O 2,048
Unit
pt, user settings without Con-
figurator
PROFIBUS-
PROFIBUS-DP remote I/O
DP Master
7,168 words
Unit
Loop Control
PID operations: 32 max.
Unit
Loop, process operations:
250 max.
Position
MECHATROLINK-II,
Control
16 axes max.
Units
supporting
MECHA-
TROLINK-II
communica-
tions
High-resolu-
MECHATROLINK II, Real
tion Motion
axes: 30, Virtual axes: 2,
Control Unit
Special motion control lan-
guage
SYSMAC
One CF card
One
SPU Unit
type I/II slot
Ethernet
(High-speed
(used with
port
Storage and
OMRON HMC-
Two
Processing
EF@@@ Mem-
Ethernet
Unit)
ory Card)
ports
Model
Number
Number
of words
of words
allocated
allocated
CIO 1500
D30000
to
CIO 1899
D31599
CS1W-
25 words
100 words Used
CLK21-V1,
CS1W-
CLK23
CS1W-
25 words
100 words Used
CLK12-V1,
CS1W-
CLK13
CS1W-
25 words
100 words Used
CLK52-V1,
CS1W-
CLK53
CS1W-
25 words
100 words Used
SLK21
CS1W-
25 words
100 words Used
SLK11
CS1W-
25 words
20 words
SCU21-V1
CS1W-
25 words
20 words
SCU31-V1
CS1W-
25 words
100 words Used
ETN01
CS1W-
25 words
100 words Used
ETN21
CS1W-
25 words
100 words Used
FLN22
CS1W-
25 words
100 words Not used
DRM21-V1
CS1W-
25 words
100 words Not used
PRM21
CS1W-
25 words
None
LC001
CS1W-
25 words
None
NCF71
CS1W-
25 words
100 words Not used
MCH71
CS1W-
Not used
Not used
SPU01
CS1W-
Not used
Not used
SPU02
Note
1. A maximum of eight Units can be mounted.
2. A maximum of four Units can be mounted.
3. A maximum of three Units can be mounted.
4. Some CPU Bus Units are allocated words in the CPU Bus Unit Setting Ar-
ea. The system must be designed so that the number of words allocated
in the CPU Bus Unit Setting Area does not exceed its capacity. Refer to 2-
7 CPU Bus Unit Setting Area Capacity for details.
CPU
Bus
CPU
C200H
Unit
Rack
Expansion
System
I/O Racks
to
Settings
Yes
No
(data link
tables)
Yes
No
(data link
tables)
Yes
No
(data link
tables)
Yes
No
(data link
tables)
Yes
No
(data link
tables)
Not used
Yes
No
Not used
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Not used
Yes
No
Not used
Yes
No
Yes
No
Not used
Yes
No
Not used
Section 2-4
Mountable Racks
CS-series
CS-series
SYSMAC
Expansion
Long-dis-
BUS Slave
Racks
tance
Racks
Expansion
Racks
Yes
Yes
No
Yes
Yes
No
Yes
Yes
No
Yes
Yes
No
Yes
Yes
No
Yes
Yes
No
Yes
Yes
No
Yes
Yes
No
Yes
Yes
No
Yes
Yes
No
Yes
Yes
No
Yes
Yes
No
No
No
No
Yes
Yes
No
Yes
Yes
No
Yes
Yes
No
Unit
Refer-
No.
ence
0 to F
W309
(See
note
1.)
---
0 to F
W367
(See
note
2.)
0 to F
W336
0 to F
W343
(See
note
2.)
0 to F
W420
(See
W421
note
2.)
0 to F
W440
(See
note
2.)
0 to F
W380
0 to F
W409
0 to F
W374
(See
W375
note
3.)
0 to F
W426
0 to F
---
0 to F
W229
127