Omron SYSMAC CS Series Operation Manual page 150

Programmable controllers
Hide thumbs Also See for SYSMAC CS Series:
Table of Contents

Advertisement

Basic System Configuration
Configuration Devices
Master Units
Unit
Model
SYSMAC BUS
C200H-RM201
Wired Remote
I/O Master Units
SYSMAC BUS
C200H-RM001-
Optical Remote
PV1
I/O Master Units
Slave Racks
Name
SYSMAC BUS Slave Rack
Backplanes
SYSMAC BUS Wired Remote
I/O Master Units
SYSMAC BUS Optical Remote
I/O Master Units
Connectable Units
Unit
CS-series
Basic I/O Units
SYSMAC BUS
No
Wired Slave
Racks
SYSMAC BUS
No
Optical Slave
Racks
112
Maximum Units
per CPU Unit
2 Units
2 Units
Note PCF: Plastic Clad Optical Fiber Cable
APF: All Plastic Optical Fiber Cable.
Model
C200H-BC101-V2
C200H-BC081-V2
C200H-BC051-V2
C200H-BC031-V2
C200H-RT201
C200H-RT202
C200H-RT001-P
C200H-RT002-P
Note Words are allocated to Units on SYSMAC BUS Slave Racks from the
SYSMAC BUS Area and not from the I/O Bit Area.
C200H Basic
I/O Units
Yes
Yes
Note
1. C200H DeviceNet Master Units (C200HW-DRM21-V1), CompoBus/S
Master Units, PLC Link Units, and SYSMAC BUS Remote I/O Master Units
cannot be connected to Wired Slave Racks.
2. Special I/O Unit words (CIO 2000 to CIO 2959) are allocated to C200H
Special I/O Units according to unit numbers.
3. Up to a total of 10 C200H Special I/O Units can be mounted to all Slave
Racks in a SYSMAC BUS Remote I/O System. Only unit numbers 0 to 9
can be used. The number of C200H Special I/O Units that can be mounted
to any one Slave Rack depends on the specific Units that are used, as
shown in the following table. For the purpose of calculating the maximum
number of Units, Units are classified into four groups, A to D.
Maximum Slave Racks and I/O
bits per CPU Unit and Master
Unit
Slave Racks
I/O bits
8
1,280
(80 words)
8
1,280
(80 words)
Specifications
10 Units
8 Units
5 Units
3 Units
Power supply voltage: 100 to
120 V AC or 200 to 240 V AC
Power supply voltage:
24 V DC
Power supply voltage: 100 to
120 V AC or 200 to 240 V AC
Power supply voltage:
24 V DC
C200H Group-2
CS-series Spe-
High-density I/O
cial I/O Units
Units (Basic I/O
Units)
No
No
No
No
Section 2-3
Slave Rack
Transmission
communica-
distance (total
tions cables
extension)
Two-core cable
200 m
Optical fiber
PCF: 200 m
cable (PCF or
APF: 20 m
APF)
(See note.)
Remarks
---
Power Supply Unit is not
required.
C200H Special
CPU Bus Units
I/O Units
Yes
No
(See note.)
Yes
No
(See note.)