PLC Setup
7-1-2-10 FINS Protection Tab Page (Protection Against FINS Writes Across
Networks) (CS-series CPU Unit Ver. 2.0 Only)
Enabling FINS Write Protection (Use FINS Write Protection)
Programming
Console address
Word
Bit(s)
+448
15
0: Disable FINS
write protection
1: Enable FINS write
protection
Default: 0
Nodes Excluded from Write Protection (Protection Releasing Addresses)
Programming
Console address
Word
Bit(s)
Set the nodes and networks from which FINS write operations will be enabled. The total number of nodes set to be
excluded from write protection will be automatically set.
A maximum of 32 nodes can be set. If these settings are not made (i.e., if the total number of nodes is 0), write operations
will be disabled for all nodes but the local node.
Note: This setting is valid only when FINS write protection has been enabled.
+449 to
8 to 15
0 to 127
480
(00 to 7F hex)
0 to 7
1 to 255
(01 to FE hex)
Note: 255 (FF hex)
can be set to include
all nodes in the
specified network.
+448
0 to 7
0 to 32
(00 to 20 hex)
366
Settings
Enables or disables write protection for the
CPU Unit from FINS command sent over a
network (i.e., all connections except for
serial connections).
Settings
FINS command source network address
FINS command source node address
Number of nodes excluded from protection
(Automatically calculated by the CX-Pro-
grammer; do not set.)
Function
Function
Section 7-1
Related
New set-
flags and
ting's
words
effective-
ness
---
At any time
Related
New set-
flags and
ting's
words
effective-
ness
---
At any time
---
---