Omron SYSMAC CS Series Operation Manual page 763

Programmable controllers
Hide thumbs Also See for SYSMAC CS Series:
Table of Contents

Advertisement

Auxiliary Area
Address
Name
Words
Bits
A394
A39400
Peripheral
to
Port PT
A39407
Communi-
cations Flag
A39408
Peripheral
to
Port PT Pri-
A39415
ority Regis-
tered Flags
A395
A39506
File Deleted
Flags
A39507
A39510
ER/AER
Flag for
Back-
ground Exe-
cution (Not
supported
by CS1@-
CPU@@
(-V1) Units)
A395
A39511
Memory
Corruption
Detected
Flag
A39512
DIP Switch
Pin 6 Sta-
tus Flag
A397
---
Simple
Backup
Write
Capacity
(Not sup-
ported by
CS1@-
CPU@@
(-V1) Units)
A400
All
Error code
Function
The corresponding bit will be ON when the peripheral
port is communicating with a PT in NT link mode.
Bits 0 to 7 correspond to units 0 to 7.
1: Communicating
0: Not communication
The corresponding bit will be ON for the PT that has
priority when the peripheral port is communicating in
NT link mode.
Bits 0 to 7 correspond to units 0 to 7.
These flags are written when the priority registration
command is received.
1: Priority registered
0: Priority not registered
The system deleted the remainder of a Memory Card
file that was being updated when a power interruption
occurred.
1: File deleted
0: No files deleted
The system deleted the remainder of an EM file mem-
ory file that was being updated when a power interrup-
tion occurred.
1: File deleted
0: No files deleted
Turns ON if an error or illegal access occurs during
background execution. Turns OFF when power is
turned ON or operation is started.
1: Error
0: No error
(Cleared when background execution is started.)
ON when memory corruption is detected when the
power supply is turned ON.
1: Memory corruption
0: Normal operation
The status of pin 6 on the DIP switch on the front of the
CPU Unit is written to this flag every cycle.
1: Pin 6 ON
0: Pin 6 OFF
If a write for a simple backup operation fails, A397 will
contain the Memory Card capacity that would have
been required to complete the write operation. The
value is in Kbytes. (This indicates that the Memory
Card did not have the specified capacity when the
write operation was started.)
A397 will be cleared to 0000 hex when the write is
completed successfully for a simple backup operation.
When a non-fatal error (user-defined FALS(006) or
system error) or a fatal error (user-defined FALS(007)
or system error) occurs, the 4-digit hexadecimal error
code is written to this word. (Refer to Details on Auxil-
iary Area Operation on page 746.) When two or more
errors occur simultaneously, the highest error code will
be recorded.
Refer to page 746 for details on error codes.
Appendix B
Status
Status at
Write timing/
after
startup
Related flags,
mode
change
Retained Cleared
Written when there is
a normal response to
the token
Retained Cleared
See Function column.
Cleared
Cleared
Written when the sys-
tem deletes the file.
Cleared
Cleared
Written when the sys-
tem deletes the file.
Cleared
Cleared
---
Retained See
Written when power is
Function
turned ON.
column.
Retained See
Written every cycle
Function
column.
Retained Retained When write is exe-
cuted
Cleared
Cleared
Written when error
occurs
settings