Additional Tools And Materials Required; Figure 3-15 General Gsu Configuration - Radwin 5000 HPMP User Manual

Point to multipoint broadband wireless
Hide thumbs Also See for 5000 HPMP:
Table of Contents

Advertisement

Additional Tools and Materials Required

Figure 3-15: General GSU configuration
See
Chapter 11
for further details about the use of RADWIN GSU.
Additional Tools and Materials Required
The following is a list of the equipment and materials required to install RADWIN 5000 HPMP
hardware.
Tools and Materials
Crimping tool for RJ-45 (if the ODU-PoE cable is without connectors)
Spanner/wrench 13 mm (½")
Drill (for wall mounting only)
Cable ties
Sealing material
Cables and connectors
ODU grounding cable 10 AWG
ODU-PoE cable (outdoor class, CAT-5e, 4 twisted pairs, 24AWG), up to 100 m. for
100BaseT connection. For a 1000BaseT connection (HBS only) use an ODU-PoE cable
no longer than 75m.
For 1000BaseT, you should use RADWIN supplied ODU-PoE cables, which
guarantee 1Gb performance. RADWIN cannot guarantee 1Gb performance
if you use third party cables.
Note
A crossed Ethernet LAN cable is required if you set up ODUs using the "Local Connec-
tion" method.
RADWIN 5000 HPMP User Manual
Release 3.3.30
Chapter 3
3-11