Additional Tools and Materials Required
Figure 3-15: General GSU configuration
See
Chapter 11
for further details about the use of RADWIN GSU.
Additional Tools and Materials Required
The following is a list of the equipment and materials required to install RADWIN 5000 HPMP
hardware.
Tools and Materials
•
Crimping tool for RJ-45 (if the ODU-PoE cable is without connectors)
•
Spanner/wrench 13 mm (½")
•
Drill (for wall mounting only)
•
Cable ties
•
Sealing material
Cables and connectors
•
ODU grounding cable 10 AWG
•
ODU-PoE cable (outdoor class, CAT-5e, 4 twisted pairs, 24AWG), up to 100 m. for
100BaseT connection. For a 1000BaseT connection (HBS only) use an ODU-PoE cable
no longer than 75m.
For 1000BaseT, you should use RADWIN supplied ODU-PoE cables, which
guarantee 1Gb performance. RADWIN cannot guarantee 1Gb performance
if you use third party cables.
Note
•
A crossed Ethernet LAN cable is required if you set up ODUs using the "Local Connec-
tion" method.