Special Considerations for Mounting an HSU-610 (AC Powered HSU)
To mount an external antenna:
1. To mount an external antenna, ensure that the antenna is properly grounded and
then mount the antenna onto the pole. Refer to
mounting instructions.
2. Follow the mounting instructions supplied with the antenna.
Special Considerations for Mounting an HSU-610 (AC Powered HSU)
The LAN and PoE cables must be fitted with lightning protection devices. See below and
Chapter 18
for detailed installation instructions of lightning protection devices.
The HSU had a rear grounding lug. Ensure that it is grounded using a wire with diameter of at
least 10 AWG.
In respect of the AC connection:
Caution
In respect of the PoE port:
Mounting the Lightning Protection Devices
The use of lightning protection is dependent on regulatory and end user requirements. The
RADWIN 5000 HPMP ODU is designed with surge limiting circuits to minimize the risk of dam-
age due to lightning strikes. RADWIN recommends the use of additional surge arrestor
devices to protect the equipment from nearby lightning strikes.
See below and
Chapter 18
devices.
Outdoor Connections
To complete the outdoor connections:
1. Connect the ground cable to the ODU chassis as marked on the ODU.
2. Connect the lightning protection device to the ODU (see
3. Attach the ODU-PoE cable to the ODU RJ-45 connector (see
connector pinout)
4. Screw in the cable glands to ensure hermetic sealing of the ODU.
5. Secure the cables to the pole, mast or brackets using UV-rated cable ties.
RADWIN 5000 HPMP User Manual
Wiring must be done by qualified personnel
Never handle the power plug under wet conditions
Connect the ground-wire prior to connecting the line-wires
An external AC surge suppression device is recommended for use
with this product. It is recommended that you use an AC line surge
suppression unit that meets the standard IEC 801-5 (EN6100-4-5)
Class 5 at +/- 6Kvolts on AC power source ground-wire and +/-
4Kvolts on line-wires
Do not connect a power supply to the PoE port of this product as it
will cause damage to the device
for detailed installation instructions of lightning protection
Release 3.3.30
Chapter 17
for detailed antenna
Chapter
18).
Appendix B
Chapter 3
for the
3-14

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents