Private MIB Parameters
Private MIB Parameters
Table C-2: Private MIB Parameters (Sheet 1 of 24)
Name
winlink1000OduAdmProductType
winlink1000OduAdmHwRev
winlink1000OduAdmSwRev
winlink1000OduAdmLinkName
winlink1000OduAdmResetCmd
winlink1000OduAdmAddres
winlink1000OduAdmMask
winlink1000OduAdmGateway
winlink1000OduAdmBroadcast
winlink1000OduAdmHostsTable
winlink1000OduAdmHostsEntry
winlink1000OduAdmHostsIndex
winlink1000OduAdmHostsIp
winlink1000OduAdmHostsPort
winlink1000OduBuzzerAdminState
winlink1000OduProductId
winlink1000OduReadCommunity
winlink1000OduReadWriteCommunity
winlink1000OduTrapCommunity
winlink1000OduAdmSnmpAgentVersion
RADWIN 5000 HPMP User Manual
OID
1.3.6.1.4.1.4458.1000.1.1.1
1.3.6.1.4.1.4458.1000.1.1.2
1.3.6.1.4.1.4458.1000.1.1.3
1.3.6.1.4.1.4458.1000.1.1.4
1.3.6.1.4.1.4458.1000.1.1.5
1.3.6.1.4.1.4458.1000.1.1.6
1.3.6.1.4.1.4458.1000.1.1.7
1.3.6.1.4.1.4458.1000.1.1.8
1.3.6.1.4.1.4458.1000.1.1.10
1.3.6.1.4.1.4458.1000.1.1.12.1.2
1.3.6.1.4.1.4458.1000.1.1.12.1.3
1.3.6.1.4.1.4458.1000.1.1.13
1.3.6.1.4.1.4458.1000.1.1.14
1.3.6.1.4.1.4458.1000.1.1.15
1.3.6.1.4.1.4458.1000.1.1.16
1.3.6.1.4.1.4458.1000.1.1.17
1.3.6.1.4.1.4458.1000.1.1.18
Release 3.3.30
Type
Description
DisplayString
RO ODU configuration description.
DisplayString
RO ODU Hardware Version.
DisplayString
RO ODU Software Version.
DisplayString
RW Link Name. A change is effective immediately.
Integer
RW Reset Command.
3 will cause a device reset. HBS only: A set
command with a value of 4 will cause a device reset
for the entire sector. The read value is always 0.
IPAddress
RW ODU IP address. A change is effective after reset.
The parameter is kept for backward compatibility.
Using the alternative parameter:
winlink1000OduAdmIpParamsCnfg is
recommended.
IPAddress
RW ODU Subnet Mask. A change is effective after
reset.
compatibility.
winlink1000OduAdmIpParamsCnfg is
recommended.
IPAddress
RW ODU default gateway. A change is effective after
reset.
compatibility.
winlink1000OduAdmIpParamsCnfg is
recommended.
Integer
RW This parameter is reserved for the Manager
application provided with the product.
N/A Trap destinations table. Each trap destination is
defined by an IP address and a UDP port. Up to 10
addresses can be configured.
N/A Trap destinations table entry. INDEX {
winlink1000OduAdmHostsIndex }
RO Trap destinations table index.
IPAddress
RW Trap destination IP address. A change is effective
immediately.
Integer
RW UDP port of the trap destination. A change is
effective immediately.
Integer
RW This parameter controls the activation of the buzzer
while the unit is in install mode. A change is
effective immediately. The valid values are:
disabled (0) enabledAuto (1) enabledConstantly(2)
advancedAuto (3).
DisplayString
RO This parameter is reserved for the Manager
application provided with the product.
DisplayString
RW Read Community String. This parameter always
returns ***** when retrieving its value. It is used by
the Manager application to change the Read
Community String. The SNMP agent accepts only
encrypted values.
DisplayString
RW Read/Write Community String. This parameter
always returns ***** when retrieving its value. It is
used by the Manager application to change the
Read/Write Community String. The SNMP agent
accepts only encrypted values.
DisplayString
RW Trap Community String. This parameter is used by
the Manager application to change the Trap
Community String. The SNMP agent accepts only
encrypted values.
Integer
RO Major version of the SNMP agent.
Appendix C
A set command with a value of
The parameter is kept for backward
Using the alternative parameter:
The parameter is kept for backward
Using the alternative parameter:
C-5