Additional Tools and Materials Required
Additional Tools and Materials Required
The following is a list of the equipment and materials required to install RADWIN 5000 HPMP
hardware.
Tools and Materials
•
Crimping tool for RJ-45 (if the ODU-PoE cable is without connectors)
•
Spanner/wrench 13 mm (½")
•
Drill (for wall mounting only)
•
Cable ties
•
Sealing material
Cables and connectors
•
ODU grounding cable 12AWG
•
ODU-PoE cable (outdoor class, CAT-5e, 4 twisted pairs, 24AWG), up to 100 m. for
100BaseT connection. For a 1000BaseT connection (HBS only) use an ODU-PoE cable
no longer than 75m.
For 1000BaseT, you should use RADWIN supplied ODU-PoE cables, which
guarantee 1Gb performance. RADWIN cannot guarantee 1Gb performance
if you use third party cables.
Note
•
A crossed Ethernet LAN cable is required if you set up ODUs using the "Local Connec-
tion" method.
Hardware Installation Sequence
The following steps are required to install a RADWIN 5000 HPMP system:
1. Mounting the ODUs, page
2. Mounting the external antennas (if used), page
3. Mounting the Lightning Protection devices (if used), page
4. Outdoor connections, page
5. Connecting the PoEs, page
6. Other Indoor connections, page
7. Aligning the HSUs to the HBS, page
See
Figure 3-8
below, which illustrates a typical installation of a RADWIN 55xx HSU with an
external antenna.
RADWIN 5000 HPMP User Manual
page
3-8.
page
3-9.
page
3-10.
page
3-10.
page
3-10.
Release 3.1.00
page
3-9.
page
3-9.
Chapter 3
3-7