Radwin Manager Traps - Radwin 5000 HPMP User Manual

Point to multipoint broadband wireless
Hide thumbs Also See for 5000 HPMP:
Table of Contents

Advertisement

More on the Thresholds
Table 9-3: HSU Performance Monitoring Fields (Continued)
Abbreviation
Column Heading
Meaning
Below Capacity Thresh
(0.0 Mbps)
Threshold set in
Above Traffic Thresh
Figure 9-7
As for the HBS, use the Save button to store the current data to file and the Clear button to
delete currently stored performance data.
More on the Thresholds
RSL Thresholds
Two RSL Thresholds can be defined. They are used as an indicator of problems in the radio
channel. You can check the RSS from the Link Budget Calculator results during installation.
Values of -5dB and -8dB from the current RSS are typical.
TSL Threshold
A counter is maintained, of the number of second intervals during which Tx power exceeds
this threshold.
BBER Threshold
The Background Block Error Ratio is measured as a percentage. The threshold can be set
from 0.1% up to 50%.
An 8% threshold is recommended. If there are no problems during the interval, then for that
threshold, the recommended BBER value should be 0. Since the system provides a lossless
Ethernet service, there is throughput degradation in case of interference. The degradation is
proportional to the BBER.
Ethernet Thresholds - Capacity
This is used as a basis for checking adherence to a Service Level Agreement. It is the number
of seconds count that the link capacity falls bellow the threshold.
Ethernet Thresholds - Traffic
The number of seconds count that received traffic exceeded this threshold. It can be used to
measure traffic peaks.

RADWIN Manager Traps

The RADWIN Manager application issues traps to indicate various events, displayed in the
Events Log.
Table 9-4: RADWIN Manager Trap Messages
Trap Message
Cannot bind to trap service port. Port 162 already in use by
ProcessName (pid: ProcessId)
Device unreachable!
Connected to <site_name>
RADWIN 5000 HPMP User Manual
Description
Seconds count when throughput fell below the threshold set in
Seconds count when actual traffic exceeded the threshold
Severity
Warning
Error
Information
Release 3.3.30
Chapter 9
Figure 9-7
Remarks
RADWIN Manager will not catch any traps from the
ODU, some other application has grabbed this
port.
Check connectivity to ODU
9-14

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents