Using More than One HSS Unit
2. The next available SYNC port of the first HSS unit should be connected to SYNC 10
of the second HSS unit as shown in
available port on the first HSS unit is SYNC 6.
3. The second HSS unit may be filled out with up to nine more ODUs in reverse
order. That is, connect SYNC 9, SYNC 8, SYNC 7... as shown in
Figure 10-7: Cascading two HSS units
4. To add a further HSS unit: Connect the next available SYNC port from the second
HSS unit in descending order (SYNC 5 in
HSS unit.
5. ODUs are connected to the third HSS unit from SYNC 2 as shown in
in ascending order:
Figure 10-8: Cascading three HSS units
6. If further ODUs are required, observe the convention that additional even
numbered units are populated in descending order from SYNC 9 and odd
numbered HSS units are populated in ascending order from SYNC 2.
If an ODU is disconnected from an HSS unit, then all remaining ODUs must
be moved up or down to maintain the connectivity.
Note