Configuring the Sector out of the Box - IP Addresses
Figure 5-2: Logging on with Local Connection
Warning
Here is the initial main display using Local Connection:
RADWIN 5000 HPMP User Manual
The Local Connection method uses broadcast packets to "discover"
the attached ODU
If you log on using Local Connection, but your physical connection
is not local (i.e. anything other than a direct connection between the
managing computer and the PoE device), then any configuration you
carry out may affect other links in the network. Do not do this!
Do not carry out this procedure using a multi homed managing com-
puter also connected to a network. It will flood the network with
broadcast packets. Further, it will throw any other links on the net-
work into Installation or Inactive mode.
In any event, as a precaution, default log-on over Local Connection is
read-only mode. Check the Read/Write enable box to carry out instal-
lation procedures.
• Network log on (IP address to the ODU) is recommended.