Mounting RADWIN Lighting Protection unit

Mounting RADWIN Lighting Protection unit
To mount a lightning protection device:
1. Mount the device as close to the ODU as possible.
2. Mount the unit to on the pole using the supplied band.
3. Connect the ODU-PoE cable using the RJ-45 jack.
4. Connect one cable between the ODU and the protector using an RJ-45 jack.
5. Connect the protector's ground stud to a grounding point. Use the appropriate wire
gauge and type, keeping the wire as short as possible, less than 1m (3'), between
the stud and the site grounding point.
There may also be regulatory requirements to cross bond the ODU-PoE CAT-
5e cable at regular intervals up the mast. This may be as frequent as every
10 meters (33 feet).
Note
A second lightning protector Unit must be mounted at the building entry point and must be
grounded, as shown in
To mount the lightning protection at the building entry point:
1. Mount the device outside the building, located as near as possible to the entrance of
the CAT 5e ODU-PoE cable.
2. Mount the unit to on the pole using the supplied band.
3. Connect the ODU-PoE cable using the RJ-45 jack.
4. Connect one cable between the PoE and the protector using an RJ-45 jack.
5. Connect the protector's ground stud to a grounding point. Use the appropriate wire
gauge and type, keeping the wire as short as possible, less than 1m (3'), between
the stud and the site grounding point.