Installing a Sector using PoE Devices
Installing a Sector using PoE Devices
A typical PoE device is a very simple unit having a power input connector and two Ethernet
ports. It is AC powered, and has a power LED.
To prepare a sector using PoE devices:
1. To connect the ODU to the PoE device, route the cable from the ODU to the PoE
device, secure the cable along its path and connect the cable to the LAN-OUT RJ-45
connector on the PoE device.
2. Connect it to AC power.
3. Repeat steps 1 to 2 for all ODUs in the sector.
Connecting User Equipment
To connect user equipment to a PoE device:
• Connect a user switch, router or any other compatible device to the PoE device RJ-45
port designated LAN-IN. Refer to
Mounting the Lightning Protection Devices
The use of lightning protection is dependent on regulatory and end user requirements. The
RADWIN 5000 HPMP ODU is designed with surge limiting circuits to minimize the risk of dam-
age due to lightning strikes. RADWIN recommends the use of additional lightning protector
devices to protect the equipment from nearby lightning strikes.
Figure 3-17: RADWIN
Refer to
Chapter 18
devices.
RADWIN 5000 HPMP User Manual
Appendix B
Lightning Protector Right:
for detailed installation instructions for use of lightning protection
Release 3.3.30
for connector pinouts.
Using RADWIN lightning protectors
Chapter 3