HBS
Figure 9-7: Setting the upper traffic threshold
To get data for display, click Get Data. The process may take a few seconds.
Here is an extract Performance Monitoring report based on 15 minutes recording:
Figure 9-8: HBS - Performance Monitoring report - Valid data
The meaning of the column headings is shown in the following table:
Table 9-2: HBS Performance Monitoring Fields
Abbreviation
Column Heading
Meaning
Integrity
Valid data flag
Date & Time
Time stamp
UAS
Unavailable Seconds
ES
Errored seconds
Severe Errored
SES
Seconds
Background Block
BBE
Error
Rx MBytes
Received Mbytes
Tx MBytes
Transmitted Mbytes
RADWIN 5000 HPMP User Manual
Description
Green tick for current and valid; Red cross for invalidated data (See example
below). Note that the Performance Monitoring data is not valid if not all the
values were stored (e.g., due to clock changes within the interval or power
up reset)
Data are recorded every 15 minutes; the last 30 days of recordings are
maintained. Roll-over is at midnight.
Seconds in which the interface was out of service.
The number of seconds in which there was at least one error block.
The number of seconds in which the service quality was low as determined
by the BBER threshold.
The number of errored blocks in an interval.
The number of Megabytes received at the specified port within the interval
The number of Megabytes transmitted at the specified port within the
interval.