Radwin 5000 HPMP User Manual page 336

Point to multipoint broadband wireless
Hide thumbs Also See for 5000 HPMP:
Table of Contents

Advertisement

Private MIB Parameters
Table C-2: Private MIB Parameters (Sheet 14 of 24)
Name
winlink1000OduPerfMonTdmDayIdx
winlink1000OduPerfMonTdmDayActiveSeconds
winlink1000OduPerfMonTxThresh1
winlink1000OduPerfMonRxThresh1
winlink1000OduPerfMonRxThresh2
winlink1000OduPerfMonBBERThresh1
winlink1000OduPerfMonEthCapacityThreshKbp
s
winlink1000OduPerfMonHighTrafficThreshKbps 1.3.6.1.4.1.4458.1000.1.6.25
winlink1000OduAgnGenAddTrapExt
winlink1000OduAgnGenSetMode
winlink1000OduAgnNTPCfgTimeServerIP
winlink1000OduAgnNTPCfgTimeOffsetFromUT
C
winlink1000OduAgnRealTimeAndDate
winlink1000OduAgnCurrAlarmLastChange
winlink1000OduAgnCurrAlarmTable
winlink1000OduAgnCurrAlarmEntry
winlink1000OduAgnCurrAlarmCounter
winlink1000OduAgnCurrAlarmSeverity
RADWIN 5000 HPMP User Manual
OID
1.3.6.1.4.1.4458.1000.1.6.20
1.3.6.1.4.1.4458.1000.1.6.21
1.3.6.1.4.1.4458.1000.1.6.22
1.3.6.1.4.1.4458.1000.1.6.23
1.3.6.1.4.1.4458.1000.1.6.24
1.3.6.1.4.1.4458.1000.1.7.1.1
1.3.6.1.4.1.4458.1000.1.7.1.2
1.3.6.1.4.1.4458.1000.1.7.2.1
1.3.6.1.4.1.4458.1000.1.7.2.2
1.3.6.1.4.1.4458.1000.1.7.2.3
1.3.6.1.4.1.4458.1000.1.7.3.1
Release 3.3.30
Type
Description
RO This table is indexed per Day number. Each interval
is of 15 minutes and the oldest is 96.
RO Parameter indicating whether the TDM service was
active. Under TDM backup link the parameter
indicates whether
Integer
RW When the Transmit power exceeds this threshold a
performance monitoring TSL1 counter is
incremented.
Integer
RW When the RX power exceeds this threshold a
performance monitoring RSL1 counter is
incremented.
Integer
RW When the RX power exceeds this threshold a
performance monitoring RSL2 counter is
incremented.
Integer
RW When the BBER exceeds this threshold a
performance monitoring BBER counter is
incremented. The units are 1/10 of a percent.
Integer
RW When the current throughput is below this threshold
the corresponding counter is incremented
Integer
RW When the current traffic is above this threshold
then corresponding counter is incremented.
Integer
RW If 'yes' is chosen the ifIndex Unit Severity Time_T
and Alarm Id from the
winlink1000OduAgnCurrAlarmTable will be bind to
the end of each private trap.
Integer
RW This parameter is reserved to the element manager
provided with the product.
IPAddress
RW IP address of the server from which the current time
is loaded.
Integer
RW Offset from Coordinated Universal Time (minutes).
Possible values: -1440..1440.
OctetString
RW This parameter specifies the real time and date
Format 'YYYY-MM-DD HH:MM:SS' (Hexadecimal).
A date-time specification:
contents
-----
2
3 month
1..31
6 minutes
0..60
8 deci-seconds
Tuesday May 26 1992 at 1:30:15 PM EDT
would be displayed as: 07 c8 05 1a 0d 1e 0f 00
( 1992 -5 -26 13:30:15 )
Integer
RO This counter is initialized to 0 after a device reset
and is incremented upon each change in the
winlink1000OduAgnCurrAlarmTable (either an
addition or removal of an entry).
N/A This table includes the currently active alarms.
When a RAISED trap is
added to the table. When a CLEAR trap is sent
the entry is removed.
N/A Entry containing the details of a currently RAISED
trap. INDEX {
winlink1000OduAgnCurrAlarmCounter }
RO A running counter of active alarms. The counter is
incremented for every new RAISED trap. It is
cleared after a device reset.
RO Current Alarm severity.
Appendix C
the backup link was active.
field octets
range
----- ------ --------
1
1-2 year
0..65536
1..12
3
4 day
4
5 hour
0..23
0..59
6
7 seconds
(use 60 for leap-second)
0..9
For example
sent an alarm entry is
C-18
5
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents