Radwin 5000 HPMP User Manual page 333

Point to multipoint broadband wireless
Hide thumbs Also See for 5000 HPMP:
Table of Contents

Advertisement

Private MIB Parameters
Table C-2: Private MIB Parameters (Sheet 11 of 24)
Name
winlink1000OduPerfMonIntervalIntegrity
winlink1000OduPerfMonIntervalCompressed
winlink1000OduPerfMonDayTable
winlink1000OduPerfMonDayEntry
winlink1000OduPerfMonDayIdx
winlink1000OduPerfMonDayUAS
winlink1000OduPerfMonDayES
winlink1000OduPerfMonDaySES
winlink1000OduPerfMonDayBBE
winlink1000OduPerfMonDayIntegrity
winlink1000OduPerfMonDayCompressed
winlink1000OduPerfMonAirCurrTable
winlink1000OduPerfMonAirCurrEntry
winlink1000OduPerfMonAirCurrMinRSL
winlink1000OduPerfMonAirCurrMaxRSL
winlink1000OduPerfMonAirCurrRSLThresh1Exc
eed
winlink1000OduPerfMonAirCurrRSLThresh2Exc
eed
RADWIN 5000 HPMP User Manual
OID
1.3.6.1.4.1.4458.1000.1.6.4.1.1
1.3.6.1.4.1.4458.1000.1.6.4.1.2
1.3.6.1.4.1.4458.1000.1.6.4.1.3
1.3.6.1.4.1.4458.1000.1.6.4.1.4
Release 3.3.30
Type
Description
RO Indicates the integrity of the entry per interval.
RO Holds a compressed string of all data per interface.
Compressed Air Interface Structure (size in
brackets):
Integrity (1)
RSLThresh1Exceeded (4)
RSLThresh2Exceeded (4) MinTSL (1) MaxTSL (1)
TSLThresh1Exceed (4) BBERThresh1Exceed (4)
RxMBytes (4)
EthCapacityThreshUnder (4)
HighTrafficThreshExceed (4)
Etherent ODU interface (size in brackets):
(4) ES (4) SES (4) BBE (4) Integrity (1)
RxMBytes (4) TxMBytes (4)
EthCapacityThreshUnder (4)
HighTrafficThreshExceed (4) ActiveSeconds (1)
N/A This table defines/keeps the counters of the last
month (in resolution of days).
N/A This is an entry in the Days Table. INDEX {ifIndex
winlink1000OduPerfMonDayIdx }
RO This table is indexed per interval number. Each
interval is of 24 hours and the oldest is 30.
RO The current number of Unavailable Seconds per
interval of 24 hours.
RO Current number of Errored Seconds per interval of
24 hours.
RO Current number of Severely Errored Seconds per
interval of 24 hours.
RO Current number of Background Block Errors per
interval of 24 hours.
RO Indicates the integrity of the entry per interval of 24
hours.
RO Holds a compressed string of all data per interface.
Compressed Air Interface Structure (size in
brackets):
Integrity (1)
RSLThresh1Exceeded (4)
RSLThresh2Exceeded (4) MinTSL (1) MaxTSL (1)
TSLThresh1Exceed (4) BBERThresh1Exceed (4)
RxMBytes (4)
EthCapacityThreshUnder (4)
HighTrafficThreshExceed (4)
Etherent ODU interface (size in brackets):
(4) ES (4) SES (4) BBE (4) Integrity (1)
RxMBytes (4) TxMBytes (4)
EthCapacityThreshUnder (4)
HighTrafficThreshExceed (4) ActiveSeconds (1)
N/A This table defines/keeps the air counters of the
current 15 min interval.
N/A This is an entry in the Current Interval Table.
INDEX {ifIndex }
Integer
RO Current Min Received Level Reference starting
from the present 15 minutes period.
Integer
RO Current Max Received Level Reference starting
from the present 15 minutes period.
Gauge
RO Number of seconds Receive Signal Level exceeded
the RSL1 threshold in the last 15 minutes.
Gauge
RO Number of seconds Receive Signal Level exceeded
the RSL2 threshold in the last 15 minutes.
Appendix C
UAS (4) ES (4) SES (4) BBE (4)
MinRSL (1) MaxRSL (1)
TxMBytes (4)
Compressed
UAS (4) ES (4) SES (4) BBE (4)
MinRSL (1) MaxRSL (1)
TxMBytes (4)
Compressed
C-15
UAS
UAS

Hide quick links:

Advertisement

Table of Contents
loading