Mounting the Ethernet Repeater
Mounting the Ethernet Repeater
The RADWIN Ethernet repeater enables you to extend the PoE to ODU cable beyond the
100m limit (but no more than 200m). The unit looks physically like the lightning protection
device in
Figure
3-17. It's use is very simple as shown in the following schematic:
Figure 3-18:
sing an Ethernet repeater with lightning protectors
The Ethernet repeater cannot be used with GbE IDU-ODU cables.
Note
Additional Waterproofing for the Lightning Protection Unit and the
Repeater
If these units are installed at locations heavily exposed to heavy dust, rain or corrosive mois-
ture (for example, close to the sea), you should protect them further as in the following pro-
cedure. In the remainder of this section, "unit" refers to either a Lightning Protection Unit or
a Repeater.
To seal a unit against excessive dust and moisture:
1. Obtain a high quality sealing material such as Scotch 23 Tape ¾" wide, from 3M to
ensure IP-67 compliant protection against water and dust.
2. Cut two pieces each 25 cm long, of Scotch 23 splicing tape. Remove the plastic cover
to expose the tacky side of the sealing tape as shown in