Radwin 5000 HPMP User Manual page 337

Point to multipoint broadband wireless
Hide thumbs Also See for 5000 HPMP:
Table of Contents

Advertisement

Private MIB Parameters
Table C-2: Private MIB Parameters (Sheet 15 of 24)
Name
winlink1000OduAgnCurrAlarmId
winlink1000OduAgnCurrAlarmIfIndex
winlink1000OduAgnCurrAlarmUnit
winlink1000OduAgnCurrAlarmTrapID
winlink1000OduAgnCurrAlarmTimeT
winlink1000OduAgnCurrAlarmText
winlink1000OduAgnLastEventsNumber
winlink1000OduAgnLastEventsTable
winlink1000OduAgnLastEventsEntry
winlink1000OduAgnLastEventsIndex
winlink1000OduAgnLastEventsSeverity
winlink1000OduAgnLastEventsIfIndex
winlink1000OduAgnLastEventsTimeT
winlink1000OduAgnLastEventsText
winlink1000IduAdmProductType
winlink1000IduAdmHwRev
winlink1000IduAdmSwRev
winlink1000OduAdmNumOfExternalAlarmIn
winlink1000OduAdmExternAlarmInTable
winlink1000OduAdmExternAlarmInEntry
winlink1000OduAdmExternAlarmInIndex
winlink1000OduAdmExternAlarmInText
winlink1000OduAdmExternAlarmInAdminState 1.3.6.1.4.1.4458.1000.2.1.5.1.3
winlink1000OduAdmExternAlarmInStatus
winlink1000IduAdmSN
winlink1000IduAdmIduDetectionMode
winlink1000IduAdmMountedTrunks
winlink1000IduAdmLicensedTrunks
winlink1000IduAdmVlanSupported
winlink1000IduAdmVlanEgressMode
winlink1000IduAdmVlanIngressMode
RADWIN 5000 HPMP User Manual
OID
1.3.6.1.4.1.4458.1000.1.7.4.1
1.3.6.1.4.1.4458.1000.1.7.4.2.1.1
1.3.6.1.4.1.4458.1000.1.7.4.2.1.2
1.3.6.1.4.1.4458.1000.1.7.4.2.1.3
1.3.6.1.4.1.4458.1000.1.7.4.2.1.4
1.3.6.1.4.1.4458.1000.1.7.4.2.1.5
1.3.6.1.4.1.4458.1000.2.1.5.1.1
1.3.6.1.4.1.4458.1000.2.1.5.1.4
Release 3.3.30
Type
Description
RO Unique Alarm Identifier (combines alarm type and
interface). The same AlarmId is used for RAISED
and CLEARED alarms.
RO Interface Index where the alarm occurred. Alarms
that are
will have the following value: 65535.
RO Unit associated with the alarm.
RO ID of the raised trap that was sent when this alarm
was raised.
RO Timestamp of this alarm. This number is in seconds
from Midnight January 1st 1970.
RO Alarm display text (same as the text in the sent
trap).
Integer
RO This counter indicates the size of the
winlink1000OduAgnLastEventsTable
N/A This table includes the last events. When a trap is
sent an event entry is added to the table.
N/A Entry containing the details of last traps. INDEX {
winlink1000OduAgnLastEventsIndex }
Integer
RO The index of the table
Integer
RO Current Trap severity.
Integer
RO Interface Index where the event occurred. Traps
that are
will have the following value: 65535.
Integer
RO Timestamp of this trap. This number is in seconds
from Midnight January 1st 1970.
DisplayString
RO Trap display text (same as the text in the sent trap).
RO IDU configuration description.
RO IDU Hardware Revision.
RO IDU Software Revision.
RO Indicates the number of currently available External
Alarm Inputs.
N/A This is the External Alarm Inputs table.
N/A Entry containing the elements of a single External
Alarm Input.
winlink1000OduAdmExternAlarmInIndex}
Integer
RO This value indicates the index of the External Alarm
Input entry.
RW This field describes the External Alarm Input. It is
an optional string of no more than 64 characters
which will be used in the event being sent as a
result of a change in the status of the External
Alarm Input. DEFVAL {Alarm Description}
Integer
RW This value indicates if this External Alarm Input is
enabled or disabled.
Integer
RO This value indicates the current status of the
External Alarm Input.
RO IDU Serial Number
RW The parameter defines whether to send Ethernet
frames to detect an IDU. The valid writable values
are: userDisabled (3) userEnabled (4).
requires a reset and is effective after reset.
RO Number of mounted trunks in the IDU
RO Number of Licensed Trunks in the IDU
RO Identifies if the local IDU supports VLAN tag/untag
RW VLAN tag/untag egress values
RW VLAN tag/untag ingress values
Appendix C
not associated with a specific interface
not associated with a specific interface
INDEX {
A change
C-19

Hide quick links:

Advertisement

Table of Contents
loading