Radwin 5000 HPMP User Manual page 328

Point to multipoint broadband wireless
Hide thumbs Also See for 5000 HPMP:
Table of Contents

Advertisement

Private MIB Parameters
Table C-2: Private MIB Parameters (Sheet 6 of 24)
Name
winlink1000OduAirDesiredRateIdx
winlink1000OduAirLinkDistance
winlink1000OduAirLinkWorkingMode
winlink1000OduAirMajorLinkIfVersion
winlink1000OduAirMinorLinkIfVersion
winlink1000OduAirHssDesiredOpState
winlink1000OduAirHssCurrentOpState
winlink1000OduAirHssSyncStatus
winlink1000OduAirHssExtPulseStatus
winlink1000OduAirHssExtPulseType
winlink1000OduAirHssDesiredExtPulseType
winlink1000OduAirHssRfpTable
winlink1000OduAirHssRfpEntry
winlink1000OduAirHssRfpIndex
winlink1000OduAirHssRfpEthChannelBW5MHz 1.3.6.1.4.1.4458.1000.1.5.40.7.1.2 Integer
winlink1000OduAirHssRfpTdmChannelBW5MH
z
winlink1000OduAirHssRfpEthChannelBW10MH
z
winlink1000OduAirHssRfpTdmChannelBW10M
Hz
winlink1000OduAirHssRfpEthChannelBW20MH
z
winlink1000OduAirHssRfpTdmChannelBW20M
Hz
winlink1000OduAirHssRfpEthChannelBW40MH
z
winlink1000OduAirHssRfpTdmChannelBW40M
Hz
RADWIN 5000 HPMP User Manual
OID
1.3.6.1.4.1.4458.1000.1.5.28
1.3.6.1.4.1.4458.1000.1.5.29
1.3.6.1.4.1.4458.1000.1.5.30
1.3.6.1.4.1.4458.1000.1.5.31
1.3.6.1.4.1.4458.1000.1.5.32
1.3.6.1.4.1.4458.1000.1.5.40.1
1.3.6.1.4.1.4458.1000.1.5.40.2
1.3.6.1.4.1.4458.1000.1.5.40.3
1.3.6.1.4.1.4458.1000.1.5.40.4
1.3.6.1.4.1.4458.1000.1.5.40.5
1.3.6.1.4.1.4458.1000.1.5.40.6
1.3.6.1.4.1.4458.1000.1.5.40.7.1.1 Integer
1.3.6.1.4.1.4458.1000.1.5.40.7.1.3 Integer
1.3.6.1.4.1.4458.1000.1.5.40.7.1.4 Integer
1.3.6.1.4.1.4458.1000.1.5.40.7.1.5 Integer
1.3.6.1.4.1.4458.1000.1.5.40.7.1.6 Integer
1.3.6.1.4.1.4458.1000.1.5.40.7.1.7 Integer
1.3.6.1.4.1.4458.1000.1.5.40.7.1.8 Integer
1.3.6.1.4.1.4458.1000.1.5.40.7.1.9 Integer
Release 3.3.30
Type
Description
Integer
RW Required Air Rate index. 0 reserved for Adaptive
Rate. A change is effective immediately after Set
operation to the master side while the link is up.
Integer
RO Link distance in meters. A value of -1 indicates an
illegal value and is also used when a link is not
established.
Integer
RO Link working mode as a result of comparing
versions of both sides of the link.
are: Unknown - no link Normal - versions on both
sides are identical with full compatibility
restricted compatibility or versions on both sides
are different with software upgrade or versions
incompatibility.
Integer
RO Major link interface version
Integer
RO Minor link interface version
Integer
RW Required Hub Site Synchronization operating state.
Integer
RO Current Hub Site Synchronization operating state.
Integer
RO Hub Site Synchronization sync status.
Integer
RO Hub Site Synchronization external pulse detection
status. In GSS mode: if generating then 1PSP is
auto generated by the GSS Unit. if
generatingAndDetecting then 1PSP is generated by
GPS satellites signal.
Integer
RO Hub Site Synchronization external pulse type.
Integer
RW Hub Site Synchronization required external pulse
type. Valid values for read write:
typeB(3) typeC(4) typeD(5) typeE(6) typeF(7)}.
Valid value for read only:
N/A ODU Radio Frame Patterns (RFP) Table.
N/A ODU RFP Table entry. INDEX {
winlink1000OduAirHssRfpIndex }
RO ODU RFP Table index. The index represent the
Radio Frame Pattern:
typeC(4) typeD(5) typeE(6).
RO Represents the compatibility of Ethernet service
under Channel BW of 5MHz
Frame Pattern.
RO Represents the compatibility of TDM service under
Channel BW of 5MHz
Pattern.
RO Represents the compatibility of Ethernet service
under Channel BW of 10MHz
Radio Frame Pattern.
RO Represents the compatibility of TDM service under
Channel BW of 10MHz
Frame Pattern.
RO Represents the compatibility of Ethernet service
under Channel BW of 20MHz
Radio Frame Pattern.
RO Represents the compatibility of TDM service under
Channel BW of 20MHz
Frame Pattern.
RO Represents the compatibility of Ethernet service
under Channel BW of 40MHz
Radio Frame Pattern.
RO Represents the compatibility of TDM service under
Channel BW of 40MHz
Frame Pattern.
Appendix C
Possible modes
with
{typeA(2)
{notApplicable(1)}.
typeA(2) typeB(3)
in the specific Radio
in the specific Radio Frame
in the specific
in the specific Radio
in the specific
in the specific Radio
in the specific
in the specific Radio
C-10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents