Name
winlink1000IduTdmTxClockDesiredState
winlink1000IduTdmTxClockActualState
winlink1000IduTdmMasterClockAvailOptions
winlink1000IduTdmMasterClockDesired
winlink1000IduTdmMasterClockActual
winlink1000IduTdmConfigTable
winlink1000IduTdmConfigEntry
winlink1000IduTdmConfigIndex
winlink1000IduTdmIfIndex
winlink1000IduTdmLineCoding
winlink1000IduTdmLoopbackConfig
winlink1000IduTdmLineStatus
winlink1000IduTdmCurrentTable
winlink1000IduTdmCurrentEntry
winlink1000IduTdmCurrentIndex
winlink1000IduTdmCurrentBlocks
winlink1000IduTdmCurrentDrops
winlink1000IduTdmCurrentTxClock
winlink1000IduTdmCurrentBlocksHigh
winlink1000IduTdmRemoteQual
winlink1000IduTdmRemoteQualEval
winlink1000IduTdmSrvEval
winlink1000IduTdmBackupAvailableLinks
winlink1000IduTdmBackupTable
winlink1000IduTdmBackupEntry
winlink1000IduTdmBackupIndex
RADWIN 5000 HPMP User Manual
OID
Release 3.3.30
Type
Description
RW Required state of the TDM Transmit Clock Control.
A change is effective after re-activation of the TDM
service.
RO Actual state of the TDM Transmit Clock Control.
RO Available options of the TDM Master Clock Control
each input status is represented by a bit. When the
option is available the bit value is 1. When the
option is unavailable the bit value is 0. The
available options are:
Trunk #1 bit 4 = Trunk #2 bit 5 = Trunk #3 bit 6 =
Trunk #4 When no options are available the
returned value is: 1
RW Required TDM Master Clock. A change is effective
after re-activation of the TDM service.
RO Actual Trunk used for TDM Master Clock.
N/A IDU TDM Links Configuration table.
N/A IDU TDM Links Configuration table entry. INDEX {
winlink1000IduTdmConfigIndex }
RO Table index.
RO Link index in the interface table.
RW This parameter applies to T1 trunks only. The
parameter controls the line coding. Setting the
value to each of the indices applies to all. A
change is effective after the next open of the TDM
service.
RW Loop back configuration table. Each of the trunks
can be set Normal Line loop back or Reverse line
loop back. A change is effective immediately.
RO Line status.
N/A IDU TDM Links Statistics table.
N/A IDU TDM Links Statistics table entry. INDEX {
winlink1000IduTdmCurrentIndex }
RO Table index (Same as
winlink1000IduTdmLineIndex).
RO Number of correct blocks transmitted to the line.
RO Number of error blocks transmitted to the line.
RW TDM Transmit Clock. A change is effective after re-
activation of the TDM service.
RO High part of the 64 bits counter Current Blocks
RO Estimated average interval between error second
events. The valid values are 1-2^31 where a value
of -1 is used to indicate an undefined state.
RO Estimated average interval between error second
events during evaluation process. The valid values
are 1-2^31 where a value of -1 is used to indicate
an undefined state.
RW Evaluated TDM service bit mask. Setting this
parameter to value that is bigger than the activated
TDM service bit mask
process for 30 seconds.
0 will stop the evaluation process immediately.
RO Number of TDM backup trunks.
N/A IDU TDM Links Statistics table.
N/A IDU TDM Links Statistics table entry. INDEX {
winlink1000IduTdmBackupIndex }
RO Table index.