Grounding
Grounding
All RADWIN products should be grounded during operation. In addition:
The ODU should be earthed by a wire with diameter of at least 10 AWG.
RADWIN 5000 HPMP ODUs must be properly grounded to protect against lightning. It
is the user's responsibility to install the equipment in accordance with Section 810 of
the National Electric Code, ANSI/NFPA No.70-1984 or Section 54 of the Canadian
Electrical Code. These codes describe correct installation procedures for grounding
outdoor units, masts, lead-in wiring and discharge units. It also lays down the size of
grounding conductors and connection requirements for grounding electrodes.
RADWIN 5000 HPMP ODUs must be grounded to a Protective Earth as described in
Chapter 18
Further, you should -
Always make the ground connection first and disconnect it last
Never connect telecommunication cables to ungrounded equipment
Ensure that all other cables are disconnected before disconnecting the ground
More detailed guidelines are supplied in
Protection against Lightning
The use of lightning protection is dependent on regulatory and end user requirements. All of
RADWIN outdoor units are designed with surge limiting circuits to minimize the risk of dam-
age due to lightning strikes. RADWIN recommends the use of additional surge arrestor
devices to protect the equipment from nearby lightning strikes.
See
Chapter 18
for detailed installation instructions of lightning protection devices.
General
It is recommended that installation of the outdoor unit be contracted to a professional
installer.
Before working on equipment connected to power lines or telecommunication lines,
you should remove jewelry or any other metallic object that may come into contact
with energized parts.
Use extreme care when installing antennas near power lines.
Use extreme care when working at heights.
When using an AC power source for RADWIN 5000 HPMP PoEs always use the AC
power adapter supplied by RADWIN.
Use the right tools. In addition to standard tools required for any kind of ODU or
antenna installation, RADWIN 5000 HPMP ODUs require additional specific tools
detailed on
page 3-11

Package Contents

The RADWIN 5000 HPMP packages include the following items:
HBS and Standard HSU Package Contents
The ODU package contains:
RADWIN 5000 HPMP User Manual
and in accordance with the Local Electrical Regulations.